科技创新与应用2024,Vol.14Issue(13):140-143,4.DOI:10.19981/j.CN23-1581/G3.2024.13.034
凝升泵振动异常原因分析与改进措施研究
李轶 1唐吴宇 1舒畅1
作者信息
- 1. 成都核总核动力研究设计工程有限公司,成都 610041
- 折叠
摘要
Abstract
The condensate lift pump is an important equipment in the cooling water system of the nuclear power plant,and the abnormal vibration of three condensate lift pumps was found during the inspection.Abnormal vibration of condensate lift pump will affect the safe operation of the unit,so it is necessary to analyze the causes of abnormal vibration and put forward countermeasures.Based on the vibration test results,the vibration characteristics of the condensate pump motor,pump body and auxiliary pipelines are analyzed deeply,and the CFD calculation and analysis of the auxiliary pipelines are carried out,the causes of the abnormal vibration of the condensate pump and its ancillary pipelines are obtained,and the corresponding countermeasures to solve the abnormal vibration of the condensate pump and its ancillary pipelines are put forward,which lays a technical foundation for solving the abnormal vibration of the condensate pump in the power plant.关键词
凝升泵/振动/异常原因/CFD/应对措施Key words
condensate pump/vibration/abnormal causes/CFD/countermeasure分类
机械制造引用本文复制引用
李轶,唐吴宇,舒畅..凝升泵振动异常原因分析与改进措施研究[J].科技创新与应用,2024,14(13):140-143,4.