内蒙古电力技术2024,Vol.42Issue(2):96-100,5.DOI:10.19929/j.cnki.nmgdljs.2024.0032
1000MW双切圆锅炉高温腐蚀原因分析
Analysis of High Temperature Corrosion Causes in 1000 MW Double Tangential Boiler
马彪 1刘成 1郭滔 2杨国辉 3马宁4
作者信息
- 1. 国家能源集团科学技术研究院有限公司,银川 710004
- 2. 国能浙能宁东发电有限公司,银川 750408
- 3. 国能宁夏电力公司,银川 750004
- 4. 国能宁东第一发电有限公司,银川 750048
- 折叠
摘要
Abstract
In response to the severe high-temperature corrosion problem of the local water-cooled wall of a 1000 MW double tangential boiler,air flow measurement and damper baffle characteristic testing are conducted through cold aerodynamic field tests,and combined with the verification of reducing gas concentration testing in the near wall area of the water-cooled wall,it is determined that the reasons are:under the misleading of large DCS data deviation,the baffle opening is unreasonable during operation,leading to severe oxygen-deficient combustion in the local area,resulting in severe high-temperature corrosion in that area.After adjusting the operating mode,the situation of oxygen-deficient combustion in the area is greatly alleviated,and the possibility of high-temperature corrosion of the water-cooled wall is greatly reduced.关键词
双切圆锅炉/高温腐蚀/还原性气体/缺氧燃烧Key words
double tangential boiler/high temperature corrosion/reducing gas/oxygen-deficient combustion分类
信息技术与安全科学引用本文复制引用
马彪,刘成,郭滔,杨国辉,马宁..1000MW双切圆锅炉高温腐蚀原因分析[J].内蒙古电力技术,2024,42(2):96-100,5.