设备监理Issue(2):33-35,39,4.DOI:10.19919/j.issn.2095-2465.2024.04.010
多工况下卸船机钢结构的静载强度分析
Static Load Strength Analysis of Steel Structure of Ship Unloader under Multiple Working Conditions
刘旸1
作者信息
- 1. 上海振华重工(集团)股份有限公司长兴分公司 上海 201913
- 折叠
摘要
Abstract
A technical analysis is conducted on the steel structure of the ship unloader.Based on the actual structure and load conditions of the ship unloader,a clear and reasonable finite element model is constructed.The corresponding conveying capacity and pitch are set for the static load strength of the steel structure of the ship unloader to predict its performance under different working conditions.The results show that under the influence of external forces,the static load strength of the steel structure of the ship unloader shows significant differences under different working conditions.The finite element simulation results and static load strength testing results are further analyzed,and the static load strength of the steel structure of the ship unloader is comprehensively evaluated.This study provides reference for engineering practice in related fields and design and optimization of the steel structure of the ship unloader.关键词
多工况/卸船机钢结构/静载强度Key words
Multiple operating conditions/Steel structure of ship unloader/Static load strength分类
通用工业技术引用本文复制引用
刘旸..多工况下卸船机钢结构的静载强度分析[J].设备监理,2024,(2):33-35,39,4.