| 注册
首页|期刊导航|西华大学学报(自然科学版)|开架发电机组冷却系统性能评估及结构改进

开架发电机组冷却系统性能评估及结构改进

谭礼斌 袁越锦 雷旭

西华大学学报(自然科学版)2024,Vol.43Issue(3):35-44,10.
西华大学学报(自然科学版)2024,Vol.43Issue(3):35-44,10.DOI:10.12198/j.issn.1673-159X.4430

开架发电机组冷却系统性能评估及结构改进

Performance Evaluation and Structure Improvement of Cooling System of Open Frame Generator Unit

谭礼斌 1袁越锦 1雷旭2

作者信息

  • 1. 陕西科技大学机电工程学院,陕西西安 710021
  • 2. 四川川浦融科技有限公司,四川成都 610000
  • 折叠

摘要

Abstract

The flow field analysis and cooling performance evaluation of the cooling system of the generator unit are helpful to confirm the total flowrate of cooling system,the distribution proportion of cooling air volume and the velocity distribution characteristics of cooling air,so as to ensure uniform flow distribution in the air duct and good cooling in the high-temperature area.Taken an open frame generator unit as the research object,the initial layout and structure design of the cooling system are designed accord-ing to the key design points of cooling system,and the flow field analysis model of the cooling system of the open frame generator unit is built by fluid flow analysis software STAR-CCM+.The results show that the air volume of cylinder head air duct accounts for 48.77%of the total air volume of engine air duct,and the air volume at the bottom of engine crankcase accounts for 6.7%,which is not conducive to the cooling of engine cylinder head and engine oil.The structural improvement design of the cooling system of the open frame generator unit is formed by adjusting the spacing between the deflector and the heat sink,chan-ging the fan cover to the form of gradually expanding line,changing the matching between the hole open-ing and the shape of the heat sink and the diversion,and increasing the air inlet area through adding more openings on pull plate.After structure improvement,the air volume of the cylinder head air duct of the unit accounts for 61.83%of the total air volume of the engine air duct,and the air volume at the bottom of en-gine crankcase accounts for 13.04%.The air volume of cylinder head air duct and the air volume at the bot-tom of engine crankcase basically meet the cooling requirements of engine cylinder temperature and oil temperature.The cooling air velocity of each air duct of the engine is evenly distributed,and the motor is well cooled,and the air inlet of the air filter comes from the outside fresh cooling air.The air velocity on the muffler surface is evenly distributed.There is no flow dead zone,and the air velocity near the exhaust pipe area is large.The cooling system of the generator unit can realize better cooling of the unit and ensure the normal and long-term operation of generator unit.The research results can provide simulation data support and theoretical reference for the layout design and structure improvement of generator unit cooling system.

关键词

发电机组/冷却系统/缸头/箱体底部/风量占比

Key words

generator unit/cooling system/cylinder head/bottom of cylinder crankcase/air volume proportion

分类

信息技术与安全科学

引用本文复制引用

谭礼斌,袁越锦,雷旭..开架发电机组冷却系统性能评估及结构改进[J].西华大学学报(自然科学版),2024,43(3):35-44,10.

基金项目

国家自然科学基金项目(51876109). (51876109)

西华大学学报(自然科学版)

OACSTPCD

1673-159X

访问量0
|
下载量0
段落导航相关论文