石油石化绿色低碳2024,Vol.9Issue(2):61-64,4.
溶剂再生塔异常波动分析与对策
Abnormal Fluctuation Analysis and Countermeasures of Solvent Regeneration Tower
黄雪琪1
作者信息
- 1. 中国石油化工股份有限公司荆门分公司,湖北荆门 448000
- 折叠
摘要
Abstract
The causes of abnormal fluctuation of solvent regeneration tower in residue hydrotreating unit were analyzed,and the optimization and adjustment measures were introduced,including adding demineralized water line on the top of the reflux drum of the regeneration tower,and adjusting operation parameters of regeneration tower,adding some fresh amine liquid and purifying amine liquid by using high precision filter technology.Finally,the product quality of the downstream device of the lean amine solution was qualified,and the SO2 emission of the tail gas of the heating furnace met the environmental protection requirements.关键词
溶剂再生/异常波动/对策/胺液Key words
solvent regeneration/abnormal fluctuation/countermeasures/amine solution引用本文复制引用
黄雪琪..溶剂再生塔异常波动分析与对策[J].石油石化绿色低碳,2024,9(2):61-64,4.