热计量供热模式下用户热舒适模型的构建OA
Establishment of thermal comfort model for heat metering households
热计量供热模式下,用户的热中性温度与可接受的热环境参数对建筑的供热能耗及区域供热动态调控策略具有重要影响.采用调研与现场测试相结合的方法,对30个热计量用户的热舒适性展开研究,构建热计量供热模式下用户的热舒适模型.结果显示:热计量供热模式下,用户的服装热阻值集中在0.36~1.01 clo,占比为88.40%,用户的热中性操作温度和预计热中性操作温度分别为24.5℃和25.7℃,实际热中性相对湿度为81.11%.
In the heat metering mode,the user's thermoneutral temperature and acceptable thermal environment parameters have an important impact on the heating energy consumption of the building and the dynamic control strategy of district heating.The thermal comfort of 30 heat metering users was studied by combining research and field test,and the thermal comfort model of users under heat metering heating mode was constructed.The results show that in the heat metering mode,the thermal resistance value of the user's clothing is concentrated in 0.36~1.01 clo,accounting for 88.40%,the user's thermoneutral operating temperature and the expected thermoneutral operating temperature are 24.5℃and 25.7℃,respectively,and the actual thermoneutral relative humidity is 81.11%.
杨秀娥;刘淑丽;张航齐;师振凯
唐山学院土木工程学院,河北 唐山 063000北京理工大学机械与车辆学院,北京 100081
土木建筑
热计量供热热舒适性热感觉可接受温度
heat meteringthermal comfortthermal sensationacceptable temperature
《节能》 2024 (004)
1-4 / 4
河北省高等学校科学技术研究项目"基于随机用热行为的住区尺度建筑供热需求研究"(项目编号:QN2023143)
评论