| 注册
首页|期刊导航|净水技术|高锰酸盐指数测定仪在多水源供水系统中的应用

高锰酸盐指数测定仪在多水源供水系统中的应用

韩宛汝 孙扬 谢文利 杨慧贤 王春虎 孙贤鹏

净水技术2024,Vol.43Issue(5):204-213,10.
净水技术2024,Vol.43Issue(5):204-213,10.DOI:10.15890/j.cnki.jsjs.2024.05.024

高锰酸盐指数测定仪在多水源供水系统中的应用

Application of Permanganate Index Tester in Multi-Source Water Supply System

韩宛汝 1孙扬 1谢文利 1杨慧贤 1王春虎 2孙贤鹏3

作者信息

  • 1. 青岛水务集团有限公司,山东青岛 266071||青岛市海润自来水集团有限公司,山东青岛 266071||青岛海诚水质监测技术有限公司,国家城市供水水质监测网青岛监测站,山东青岛 266034
  • 2. 青岛水务集团有限公司,山东青岛 266071
  • 3. 青岛水务集团有限公司,山东青岛 266071||青岛市海润自来水集团有限公司,山东青岛 266071
  • 折叠

摘要

Abstract

At present,most domestic water supply monitoring laboratories use the national standard titration method to measure the permanganate index,which is cumbersome and prone to manual errors.However,the development and application research of instrument detection methods are still not systematic and comprehensive.This paper established an instrument detection method suitable for measuring the permanganate index in drinking water,seawater desalination water,and source water through experimental screening of the heating time,heating power,temperature compensation,titration zone temperature and other conditional parameters of the intelligent permanganate index measuring instrument,and explores the laws and reasons affected by altitude conditions.The study used this instrument method to determine pure water with low,medium,and high concentrations and actual water quality control samples.The experimental results showed that the relative standard deviation was 0.35%~4.55%,and the recovery rate was 87.9%~104.6%,all of which were better than the national standard titration method.In addition,this method was applied to the determination of permanganate index in actual samples,and its relative deviation from the national standard titration method was 0.60%~3.39%.Two batches of 50 actual water samples were tested continuously,with standard deviations of 3.37%and 3.77%,respectively.Its detection limit,lower detection limit,precision,accuracy,and stability can meet the requirements for continuous detection of permanganate index in multiple types of water samples such as drinking water,desalinated seawater,and raw water,and has broad practical application prospects.

关键词

高锰酸盐指数/智能测定仪法/国标滴定法/多水源供水/海水淡化水

Key words

permanganate index/intelligent instrument method/national standard titration method/multi-source water supply desalinated seawater

分类

土木建筑

引用本文复制引用

韩宛汝,孙扬,谢文利,杨慧贤,王春虎,孙贤鹏..高锰酸盐指数测定仪在多水源供水系统中的应用[J].净水技术,2024,43(5):204-213,10.

基金项目

国家重点研发计划(2022YFF0609104) (2022YFF0609104)

净水技术

OACSTPCD

1009-0177

访问量0
|
下载量0
段落导航相关论文