| 注册
首页|期刊导航|噪声与振动控制|噪声比对测试误差值探讨

噪声比对测试误差值探讨

张飞 白煜 郝影 汪贇 李宪同

噪声与振动控制2024,Vol.44Issue(3):229-232,4.
噪声与振动控制2024,Vol.44Issue(3):229-232,4.DOI:10.3969/j.issn.1006-1355.2024.03.035

噪声比对测试误差值探讨

Discussion on Measurement Errors of Noise Contrast Test

张飞 1白煜 2郝影 3汪贇 4李宪同4

作者信息

  • 1. 咸阳市生态环境局 淳化分局淳化县环境监测站,陕西 咸阳 711299
  • 2. 南京航空航天大学 经济与管理学院,南京 210016||中国环境保护产业协会,北京 100037
  • 3. 天津市生态环境监测中心,天津 300191
  • 4. 中国环境监测总站,北京 100012
  • 折叠

摘要

Abstract

Multiple field tests on noise sources of different type are carried out by using different instruments and the error ranges of using different instruments under different working conditions are analyzed to provide some references for noise field comparison tests and new instrument acceptance.The research results show that within the sound pressure level range of 40-80 dB,when using different instruments to conduct synchronous monitoring at the same measuring point which is relatively close to the same noise source,95%of the comparison errors can be controlled within±1.0 dB;more than 90%of the comparison errors are within±0.8 dB;more than 85%of the comparison errors are within±0.7 dB.The greater the intensity of the sound source is and the longer the test time is,the smaller the comparison errors are.

关键词

声学/噪声比对/噪声误差/噪声监测/噪声仪器

Key words

acoustics/noise comparison/noise errors/noise monitoring/noise instrument

分类

能源科技

引用本文复制引用

张飞,白煜,郝影,汪贇,李宪同..噪声比对测试误差值探讨[J].噪声与振动控制,2024,44(3):229-232,4.

噪声与振动控制

OA北大核心CSTPCD

1006-1355

访问量0
|
下载量0
段落导航相关论文