摘要

Abstract

The horizontal low cyclic reversed loading test of full-scale steel frame-grouting light steel shear wall structure is carried out,the coupling effect of grouting light steel shear wall and steel frame is studied,and the failure mode,stress characteristics and energy dissipation mechanism of the structure are analyzed.The bearing capacity,lateral stiffness,ductility and energy dissipation capacity of the structure are obtained.Compared with the test results of pure steel frame and cold-formed thin-walled steel grouting wall,it is found that the grouting light steel shear wall is connected with steel frame by self-tapping screw,and the two have good cooperative performance.The shear bearing capacity and lateral stiffness of frame-shear structure are 1.50 times and 1.64 times of the sum of steel frame and wall respectively,the ductility coefficient of structure is 5.42,and the seismic performance is excellent.The research results can provide a scientific basis for the design and research of this kind of structures.

关键词

钢框架-灌浆轻钢剪力墙结构/低周往复加载试验/耦合效应/抗震性能

Key words

steel frame-grouting light steel shear wall structure/low cyclic reversed loading test/coupling effect/seismic performance

分类

建筑与水利

引用本文复制引用

张铮,郭贺贺,林韩,胡凤翔..钢框架-灌浆轻钢剪力墙结构抗震性能试验研究[J].建筑钢结构进展,2024,26(5):31-41,11.

基金项目

福建省自然科学基金(2022J01927),福州市科技计划项目(2018-G-56) (2022J01927)

建筑钢结构进展

OA北大核心CSTPCD

1671-9379

访问量0
|
下载量0
段落导航相关论文