| 注册
首页|期刊导航|中国电机工程学报|自触型低压混合式直流断路器系统设计与开断特性研究

自触型低压混合式直流断路器系统设计与开断特性研究

张照资 高偲智 汪倩 陈思磊 葛世伟 李兴文

中国电机工程学报2024,Vol.44Issue(11):4544-4555,中插32,13.
中国电机工程学报2024,Vol.44Issue(11):4544-4555,中插32,13.DOI:10.13334/j.0258-8013.pcsee.230085

自触型低压混合式直流断路器系统设计与开断特性研究

System Design and Breaking Characteristics Research of Self-triggered Low Voltage Hybrid DC Circuit Breaker

张照资 1高偲智 1汪倩 2陈思磊 3葛世伟 4李兴文1

作者信息

  • 1. 电力设备电气绝缘国家重点实验室(西安交通大学),陕西省 西安市 710049
  • 2. 西安理工大学理学院,陕西省 西安市 710054
  • 3. 西安理工大学电气工程学院,陕西省 西安市 710054
  • 4. 浙江天正电气股份有限公司,浙江省 温州市 325604
  • 折叠

摘要

Abstract

The low voltage hybrid DC circuit breaker has the advantages of low power consumption,high breaking performance and selective protection,which can better meet the new development needs of photovoltaic,energy storage systems and zero carbon buildings.In this paper,a self-triggered low-voltage DC hybrid switch topology is proposed.First,through the analysis of the working principle of the hybrid circuit breaker,the electromechanical-coupling design method based on arc power supply and drive is proposed.This method uses the arc energy to supply energy to the electronic circuit,and uses the arc voltage as the control signal for the conduction of the converter branch to realize the automatic triggering of the system under short circuit fault.And the theoretical basis for the design of core functional modules is described.On this basis,a low voltage hybrid circuit breaker prototype is developed and the feasibility of the scheme is demonstrated.Finally,the influence rules of different factors on the breaking characteristics are compared and analyzed.Experiments show that compared with the traditional mechanical switch,the little current breaking time is reduced by 85.4%,and the arc energy is reduced by 94.1%,which improves the service life of the circuit breaker,and can successfully break 1.1 kA short-circuit current.It is pointed out that the overall response time of the system is positively related to the voltage rise rate at the initial stage of arcing.The increase of arc conductance and branch parasitic inductance will extend the commutation time.The arc reignition probability is mainly affected by the external system parameters.It may provide basis for the optimization design and performance improvement of low-voltage DC hybrid circuit breakers.

关键词

低压直流系统/混合式断路器/断路器寿命/小电流开断/短路开断

Key words

low voltage DC system/hybrid circuit breaker/circuit breaker life/little current breaking/short circuit breaking

分类

信息技术与安全科学

引用本文复制引用

张照资,高偲智,汪倩,陈思磊,葛世伟,李兴文..自触型低压混合式直流断路器系统设计与开断特性研究[J].中国电机工程学报,2024,44(11):4544-4555,中插32,13.

基金项目

国家自然科学基金项目(52277163) (52277163)

陕西省科技计划项目(2022TD-59). Project Supported by National Natural Science Foundation of China(52277163) (2022TD-59)

Shaanxi Provincial Science and Technology Plan Project(2022TD-59). (2022TD-59)