Abstract
Objective:To establish GC method for determination of residual organic solvent Trichloromethane and Benzene in cinnariz-ine API.Methods:GC was used with DB-624(60 m × 0.32 mm × 1.80 μm)Capillary column.The detector was FID,Inlet temperature was 250 ℃.Temperature programming:the initial column temperature was 55 ℃,kept for 10 min,and then rised to 220 ℃ with a rate of 20 ℃·min-1 and kept for 5 min.The detector temperature was 280 ℃.The flow rate was 3.0 mL·min-1;split ratio was 5∶1.Headspace sampling was used with an temperature of equilibrium at 90 ℃ and an equilibrium time 20 min.Results:The linear equations of trichloromethane(1.50-18.04 μg·mL-1)and benzene(0.050-0.603μg·mL-1)were in good linear range(r>0.999).The average recovery of trichloromethane and benzene were 97.5%(RSD=2.0%)and 97.7%(RSD=3.1%).Conclusion:The method is sensitive and accurate with good reproducibility,which can be used to determine the contents of trichloromethane and benzene in cinnariz-ine API.关键词