制冷学报2024,Vol.45Issue(3):120-128,9.DOI:10.3969/j.issn.0253-4339.2024.03.120
R32泄漏检测位置对室内安全性的影响
Influence of R32 Leak Detection Position on Indoor Safety
摘要
Abstract
In this study,the leakage diffusion and concentration distribution characteristics of R32 refrigerants from a wall-mounted split air-conditioner indoor unit are analyzed by combining experiments and simulations under different leak locations,refrigerant leak rates,and operating conditions.Safety is compared and evaluated based on whether the R32 mass fraction reaches the R32 refrigerant detector alarm concentration(4%LFL),the positions of the responsive detectors,and the lower flammability limit(LFL)area.The results show that the response time of the detectors inside the indoor unit is approximately 40 s and 50%faster than that located in the room.The experimental and numerical results show a high consistency.The diffusion law of R32 is different at different leak locations.The leak rate of R32 slightly influences the concentration distribution in the indoor unit.The area where the 4%LFL is reached when the air conditioning is ventilated is four times smaller than when the air conditioning is turned off.The best position to install the R32 refrigerant detector is the lower area between the electrical box and the front heat exchanger.When R32 leaks at the fin of the heat exchanger,the R32 refrigerant detector fails to respond,and the refrigerant continues to leak into the room,posing a safety hazard.The LFL volume is approximately 3×10-6 m3.The LFL region is a small area around the R32 leak port,and its safety risk is low.关键词
制冷剂泄漏/安全性评价/扩散规律/浓度分布/可燃区域Key words
refrigerant leakage/safety evaluation/diffusion law/concentration distribution/flammable area分类
通用工业技术引用本文复制引用
张文强,郭官明,郭小惠,孟建军,张恒..R32泄漏检测位置对室内安全性的影响[J].制冷学报,2024,45(3):120-128,9.基金项目
本文受青岛西海岸新区自主创新重大专项基金项目(2020-11)资助.(The project was supported by the Qingdao West Coast New Area Major Program of Independent Innovation(No.2020-11).) (2020-11)