| 注册
首页|期刊导航|储能科学与技术|储热系统优化对延庆冬奥村供暖经济性的影响

储热系统优化对延庆冬奥村供暖经济性的影响

凡烈 邢永杰 刘芳 熊亚选

储能科学与技术2024,Vol.13Issue(6):2057-2067,11.
储能科学与技术2024,Vol.13Issue(6):2057-2067,11.DOI:10.19799/j.cnki.2095-4239.2024.0158

储热系统优化对延庆冬奥村供暖经济性的影响

Thermal storage system optimization toward the economic viability of heating systems in Yanqing Winter Olympics Village

凡烈 1邢永杰 2刘芳 1熊亚选1

作者信息

  • 1. 北京建筑大学环境与能源工程学院,北京 102616
  • 2. 北京市科学技术研究院资源环境研究所,北京 100089
  • 折叠

摘要

Abstract

To enhance the operational economy of heating systems in winter sports venues after the Olympics,a physical-mathematical model of the thermal storage device from the venue's heating system's was constructed.Numerical simulation methods were employed to study the thermal storage device.The simulated results of temperature stratification within the thermal storage device were compared and analyzed against field-measured data,validating the accuracy of the model.The structure and temperature scheme of the thermal storage device were optimized by leveraging the local peak-valley electricity price system,aiming to optimize the operating costs of electrode boilers,with constraints the cavitation margin of the heat release pump and the total power of the electrode boiler.The influence of the thermal storage device's manifold distributor structure and thermal storage media temperature on the energy conservation and the economic viability of the heating system were investigated.Results indicate that the designed diffuser-type manifold distributor structure outperforms the manifold distributor structure in the Yanqing Winter Olympics Village's thermal storage device,as it exhibits superior temperature stratification within the thermal storage device during operation.This results in lower mixing of the thermal storage media at different temperatures within the device,which,in turn,lead to higher outlet temperatures and further improvement of the room comfort.The heating efficiency improved from 82.02%to 85.98%after optimization.During the period from winter solstice to New Year's day,the optimal temperature of the thermal storage media was 95℃,leading to a reduction in the operational costs of the electrode boiler heating system by up to 14.13%.This work highlights the value of engineering applications and provides guidance for post-Olympic venue operations and operational improvements in thermal storage heating systems.

关键词

冬奥场馆/供热系统/储热装置/性能优化/经济性

Key words

Winter Olympic venues/heating system/thermal storage devices/performance optimization/economics

分类

建筑与水利

引用本文复制引用

凡烈,邢永杰,刘芳,熊亚选..储热系统优化对延庆冬奥村供暖经济性的影响[J].储能科学与技术,2024,13(6):2057-2067,11.

基金项目

国家重点研发计划课题(2020YFF0305504). (2020YFF0305504)

储能科学与技术

OA北大核心CSTPCD

2095-4239

访问量0
|
下载量0
段落导航相关论文