Abstract
In the design of conventional air conditioning water system,the temperature difference between supply and return water is usually 5℃.This paper introduces a large temperature difference water system,which is used in chilled water and cooling water system of air conditioning.By comparing the large temperature difference with the conventional 5℃ temperature difference,this paper expounds the advantages of large temperature difference in reducing the total energy consumption of air conditioning system and the investment of supporting equipment,and compares the influence of large temperature difference on the refrigeration of terminal equipment,aiming at providing ideas for building high performance air conditioning system and reducing the overall energy consumption of air conditioning system.关键词
大温差水系统/高性能空调系统/空调能耗Key words
large temperature difference water system/high-performance air conditioning systems/total energy consumption of air condition system分类
建筑与水利引用本文复制引用