|国家科技期刊平台
首页|期刊导航|环境与职业医学|低温等离子体空气净化器在高速公路收费岗亭的干预效果分析

低温等离子体空气净化器在高速公路收费岗亭的干预效果分析OA北大核心CSTPCD

Intervention effect of low temperature plasma air purifier in highway toll booths

中文摘要英文摘要

[背景]高速公路收费站空气污染严重,收费人员存在较高的职业暴露风险,亟须研发适用于高速公路收费岗亭气载颗粒物和微生物病原体的净化方法. [目的]验证低温等离子体空气净化器对高速公路收费岗亭室内气载颗粒物和微生物的净化效果. [方法]基于对照干预实验设计,选取某高速公路收费站三个收费岗亭作为测点,开展 6 d的现场对照干预实验(无干预期:前3 d未开启低温等离子体净化器;干预期:后3 d每天9:00-17:00开启净化器).实验期间持续监测室内外等效直径小于 2.5 μm(PM2.5)和小于 10 μm(PM10)的可吸入颗粒物浓度;每天上午(9:00)、中午(12:00)和下午(17:00),使用浮游微生物采样器采集收费岗亭室内外空气样品,分析气载细菌总数;每天 9:00-17:00采用智能中流量颗粒物采样器持续采集最外侧出站口室内的气载颗粒样品,使用基因测序分析样品内含细菌和真菌种属明细及其相对丰度.采用独立样本t检验比较干预期和无干预期室内气载PM2.5、PM10 和细菌总数的浓度差异;采用α多样性分析、β多样性分析和t检验(两组比较),比较干预期 3 d和无干预期 3 d气载颗粒样品内含细菌和真菌具体种属及样品内含典型致病细菌和真菌病原体种属的物种多样性和相对丰度差异,以反映低温等离子体空气净化器对气载PM2.5、PM10 和微生物的净化效果. [结果]干预期室内PM2.5 和PM10 浓度及细菌总数的均值均低于无干预期室内均值(P<0.01或P<0.001);干预期 PM2.5 和 PM10 的室内浓度/室外浓度值(I/O)均低于无干预期(P<0.001);但干预期细菌总数的I/O值与无干预期比较,差异无统计学意义.以上午 9:00收费岗亭室内PM2.5 的平均浓度为基准,中午 12:00和下午 17:00的室内PM2.5 平均净化率分别为49.0%和 46.1%,PM10 为 49.7%和 45.4%,细菌总数为 50.8%和 49.9%.β多样性分析显示干预期和无干预期细菌种水平,真菌属水平和种水平上的物种组成成分均存在差异.与无干预期相比,干预期颗粒样品内含乳杆菌属等 10种细菌和圆酵母菌属等 7种真菌的相对丰度更低,但干预期枝孢霉科未分类属、多臂菌属和尾孢菌属真菌的丰度更高(均P<0.05).对于典型致病菌,干预期乳杆菌属细菌和狭窄梭菌属细菌的相对丰度分别降低了 73.5%和 86.9%,干预期篮状菌属真菌降低了53.5%,差异均有统计学意义(P<0.05). [结论]低温等离子体空气净化器对高速公路收费岗亭室内气载PM2.5、PM10 和浮游细菌具有较好的净化效果,但对室内气载颗粒内含部分真菌的净化作用可能有限.

[Background]The serious air pollution of highway toll booths poses a high occupational exposure risk to toll collectors.It is urgent to develop purification methods suitable for airborne particles and microbial pathogens in highway toll booths. [Objective]To verify the purification effect of low temperature plasma air purifiers on airborne particles and microbes in highway toll booths. [Methods]Based on controlled-intervention design,we selected three toll booths in an expressway toll station as on-site experimental locations for 6 d(no-intervention period:the low-temperature plasma purifier was turned off in the first three days;intervention period:the purifier was turned on from 9:00 to 17:00 in the following three days).The indoor and outdoor PM2.5 and PM10 concentrations were continuously monitored during the study.At 9:00,12:00,and 17:00 of every day during the experiment,indoor and outdoor air samples were collected to analyze the concentration of airborne culturable colonies with a plankton sampler.Airborne particle samples were col-lected in the outermost exit continuously from 9:00 to 17:00 every day during the experiment using a medium flow particulate sampler,and the species and relative abundance of fungi and bacteria contained in the samples were analyzed by gene sequencing.Independent-sample t test was used to compare the concentration of indoor PM2.5,PM10,and culturable colonies between the intervention period and the non-intervention period.α diversity analysis,β diversity analysis,and t test were used to compare the diversity and relative abundance of specific species of bacteria and fungi,as well as typical pathogenic bacteria and fungi in the samples between the non-intervention period and the intervention period to reflect the purification effect of low temperature plasma air purifier on airborne PM2.5,PM10,and microor-ganisms. [Results]During the intervention period,the mean indoor concentrations of PM2.5,PM10,and culturable colonies were lower than those of the no-intervention period(P<0.01 or P<0.001).The ratios of indoor to outdoor concentration(I/O)of PM2.5 and PM10 during the in-tervention period were significantly lower than those of the no-intervention period(P<0.001),except the I/O of culturable colonies.Compared with the average concentration at 9:00,the average cleaning rates at 12:00 and 17:00 for PM2.5 were 49.0%and 46.1%,for PM10 were 49.7%and 45.4%,for airborne culturable colonies were 50.8%and 49.9%,respectively.The β diversity analysis showed that there were significant differences in composition at the level of species of bacteria,and at the levels of genus and species of fungi between the intervention and the no-intervention periods.The relative abundances of 10 species of bacteria such as Lactobacillus and 7 species of fungi such as Torula in the intervention period were significantly lower than those in the non-intervention period,but the relative abun-dances of fungi such as unclassified_f_cladosporiaceae,trichomerium,and cercospora were higher(P<0.05).For typical pathogenic bac-teria,the relative abundances of Lactobacillus and Clostridium_sensu_stricto_1 during the intervention period were 73.5%and 86.9%lower than those in the no-intervention period,and the relative abundance of Talaromyces was 53.5%lower(P<0.05). [Conclusion]Low temperature plasma air purifier has a good purification effect on indoor PM2.5,PM10,and culturable colonies in highway toll booths,and likely a limited effect on some fungi.

刘松荣;周世军;肖燕萍;周鹏;晏致涛;马非;钟永力;蔡姣;刘炜

浙江交投高速公路运营管理有限公司技术研发中心,浙江杭州 310020重庆科技大学 建筑工程学院,重庆 401331||重庆科技大学 健康环境研究院,重庆 401331重庆科技大学 建筑工程学院,重庆 401331重庆科技大学 建筑工程学院,重庆 401331||重庆科技大学 健康环境研究院,重庆 401331||重庆市能源投资集团科技有限责任公司,重庆 400061

预防医学

低温等离子体收费岗亭可吸入颗粒物细菌总数基因测序净化效果

low temperature plasmatoll boothinhalable particleculturable colonygene sequencingpurification effect

《环境与职业医学》 2024 (005)

474-481 / 8

浙江省交通运输厅科技计划项目(202215);国家自然科学基金资助项目(52208096);重庆市自然科学基金面上项目(cstc2021jcyj-msxmX0614)

10.11836/JEOM23317

评论