研究针对北方某铅酸蓄电池回收厂拆解废铅酸蓄电池车间的拆解废酸进行单价选择性电渗析回收试验,并考察了操作电流密度、电压及流量对单价选择性电渗析工艺的影响,以期为铅酸蓄电池回收工业清洁生产提供技术支撑.在电压为5 V,电流密度为20 mA/cm2,进水流量为150 L/h,电渗析装置运行时间为48 min的条件下,回收室中H+透过率可达到80%,单价选择性电渗析对H+有较高透过率.同时,单价选择性电渗析对金属离子保持较低的泄漏率,Pb2+泄漏率为0.6%,Zn2+泄漏率为2.8%,Cd2+泄漏率为1.8%.研究实现了对废铅酸蓄电池拆解废酸中H+与重金属离子的选择性分离的目标.

In order to provide technical support for the clean production of lead-acid battery recycling industry,this study investigated the effects of current density,voltage and flow rate on the single-unit selective electrodialysis process of a lead-acid battery recycling plant in northern China.Under the conditions of voltage of 5 V,current density of 20 mA/cm2,influent flow rate of 150 L/h and operation time of electrodialysis unit of 48 min,the H+transmittance in the recovery chamber could reach 80%,and the unit price selective electrodialysis had a higher transmittance to H+.At the same time,univalent selective electrodialysis maintained a low leakage rate for metal ions,with Pb2+leakage rate of 0.6%,Zn2+leakage rate of 2.8%,and Cd2+leakage rate of 1.8%.In this study,the objective of selective separation of H+from heavy metal ions in waste acid disassembly of lead-acid batteries was achieved.

徐守疆;刘咏;李国才;张传亮;邵天宝;吴英震

泉州市海丝节水科技有限公司,福建泉州 362000天津市生态环境科学研究院,天津 300191自然资源部天津海水淡化与综合利用研究所,天津 300192

环境科学

单价选择性电渗析铅酸蓄电池废硫酸酸性重金属废水酸回收选择性分离

monovalent selective electrodialysislead-acid batterywaste sulfuric acidacid heavy metal wastewateracid recyclingselective separation

《净水技术》 2024 (006)

127-134,195 / 9

国家重点研发计划(2023YFEO101000)

10.15890/j.cnki.jsjs.2024.06.015

评论