机械制造与自动化2024,Vol.53Issue(3):99-104,6.DOI:10.19344/j.cnki.issn1671-5276.2024.03.021
CFRP沉头孔锪窝深度误差对连接性能的影响
Effect of CFRP Countersunk Hole Socket Depth Error on Connection Performance
戴仡智 1郝浩杰 2邱建平 2赵喜东 3齐振超 1陈文亮1
作者信息
- 1. 南京航空航天大学机电学院,江苏南京 210016
- 2. 中航工业西安飞机工业(集团)有限责任公司,陕西西安 710089
- 3. 中国长峰机电技术研究院,北京 100854
- 折叠
摘要
Abstract
Although countersunk bolt connection can ensure a good structure of aerodynamic shape and is often used in aircraft skin and other structures,a large error in the depth of countersink socket in the preparation process of countersunk holes is likely to occur due to limited equipment conditions,which brings hidden dangers to the composite laminated structure.To solve the problem,by combineing finite element simulation analysis,conducts a static tensile test of single nail and single shear,and studies the influence of countersink depth error on CERP connection performance.The results show that the shallower countersink socket has less effect on the static strength compared with the standard fossa depth value in the flush state,and the deeper countersink will lead to the decrease of the static strength of the structure,and the deeper the countersink socket is,the faster the static strength decreases.关键词
螺栓连接/沉头孔/锪窝深度误差/连接性能Key words
bolted connection/countersunk hole/countersink depth error/connection performance分类
机械制造引用本文复制引用
戴仡智,郝浩杰,邱建平,赵喜东,齐振超,陈文亮..CFRP沉头孔锪窝深度误差对连接性能的影响[J].机械制造与自动化,2024,53(3):99-104,6.