理化检验-物理分册2024,Vol.60Issue(6):42-45,4.DOI:10.11973/lhjy-wl230377
某电厂锅炉水冷壁管壁厚异常减薄原因
Causes of abnormal wall thickness thinning of boiler water wall in a power plant
高大伟1
作者信息
- 1. 中国大唐集团科技创新有限公司,保定 071703
- 折叠
摘要
Abstract
In the process of anti-wear and explosion-proof inspection of water wall tubes in a power plant,it was found that the wall thickness of a large number of water wall tubes was abnormally thinned.The causes of abnormal wall thickness thinning were analyzed by means of macroscopic observation,chemical composition analysis,mechanical property test,metallographic examination,scanning electron microscopy and energy spectrum analysis.The results show that the main reason for the abnormal thinning of the water wall tube to the fire side was the high temperature corrosion of the sulfide on the fire side tube wall,which eventually led to the abnormal thinning of the water wall tube wall thickness.关键词
SA-210C钢/水冷壁/高温腐蚀/壁厚减薄/硫化物Key words
SA-210C steel/water wall/high temperature corrosion/wall thickness thinning/sulfide分类
能源科技引用本文复制引用
高大伟..某电厂锅炉水冷壁管壁厚异常减薄原因[J].理化检验-物理分册,2024,60(6):42-45,4.