四川环境2024,Vol.43Issue(3):79-83,5.DOI:10.14034/j.cnki.schj.2024.03.011
成都地铁环境氡浓度与γ辐射水平调查研究
Investigation and Research on Radon Concentration and Gamma Radiation Level in Chengdu Metro
摘要
Abstract
Purpose:Understand the radon concentration and gamma radiation in the air of Chengdu Metro.Methods:The solid track etching method and the instantaneous measurement method were used to investigate the radon concentration and gamma radiation dose in Chengdu Metro stations,and the measured data were compared and analyzed.Results:The results showed that the measured range of radon concentration in Chengdu Metro was(9.7~32.5)Bq/m3,and the average radon concentration was(18.4±4.3)Bq/m3 which was lower than that in other cities in China.The range of gamma dose rates in Chengdu Metro stations was(74.9~82.6)nSv/h,and the mean value was(78.8±1.0)nSv/h which was lower than the mean value of indoor gamma dose rate in Chengdu area.It was estimated that the effective dose of metro staff caused by radon inhalation and gamma radiation exposure in the metro environment was about 0.30 mSv/a,which was far lower than the standard limit.Conclusion:The investigation showed that radon concentration and gamma radiation in Chengdu Metro did not pose additional radiation hazards to the metro staff.关键词
成都地铁/氡浓度/γ辐射剂量/有效剂量Key words
Chengdu Metro/radon concentration/gamma radiation dose/effective dose分类
资源环境引用本文复制引用
徐立鹏,王先良,刘敏,邓疆鹏,钱骏,唐辉..成都地铁环境氡浓度与γ辐射水平调查研究[J].四川环境,2024,43(3):79-83,5.基金项目
国家自然科学基金国家重大科研仪器研制项目(42127807) (42127807)
四川省自然科学基金项目(2023NSFSC0711) (2023NSFSC0711)
四川省自然科学基金项目(23NSFSCC0116) (23NSFSCC0116)