| 注册
首页|期刊导航|肿瘤预防与治疗|光梭径向采集技术和三维容积内插快速扰相序列在MRI肝脏增强扫描中的图像质量比较

光梭径向采集技术和三维容积内插快速扰相序列在MRI肝脏增强扫描中的图像质量比较

张宇 邓和平 何长久 杨学刚 胡仕北 周鹏

肿瘤预防与治疗2024,Vol.37Issue(6):492-498,7.
肿瘤预防与治疗2024,Vol.37Issue(6):492-498,7.DOI:10.3969/j.issn.1674-0904.2024.06.006

光梭径向采集技术和三维容积内插快速扰相序列在MRI肝脏增强扫描中的图像质量比较

Comparison of Image Quality between United Compressed Sensing with Radial Acquisition and Quick3D in Enhanced MRI of Liver

张宇 1邓和平 1何长久 1杨学刚 1胡仕北 1周鹏1

作者信息

  • 1. 610041 成都,四川省肿瘤临床医学研究中心,四川省肿瘤医院·研究所,四川省癌症防治中心,电子科技大学附属肿瘤医院影像科
  • 折叠

摘要

Abstract

Objective:To compare the image quality between united compressed sensing with radial acquisition(uCSR)and three-dimensional volume interpolation fast scrambling phase sequence(quick3D)in enhanced MRI of liver,and explore the value of uCSR in enhanced MRI of liver.Methods:Seventy-seven patients undergoing enhanced MRI of liver who had both uCSR and quick3D images were retrospectively collected from October 2022 to April 2023.Subjective image quality(o-verall image quality,liver edge sharpness,hepatic portal vein clarity,hepatic vein clarity and respiratory motion artifacts)and objective image quality including signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)were compared between uCSR and quick3D sequences.Results:The subjective scores and CNR of uCSR were higher than those of quick3D in 77 pa-tients(all P<0.05),and there was no significant difference in SNR between the two sequences(all P>0.05).The uCSR showed lower overall image quality and liver edge sharpness,higher hepatic portal vein clarity than quick3 D in 47 patients with good breath holding,the differences were statistically signif-icant(all P<0.05).There were no significant differences in other subjective scores,SNR and CNR between two groups(all P>0.05).The subjective and objective image qualities of uCSR were higher than those of quick3D in 30 patients with poor breath holding(all P<0.05).Conclusion:In enhanced MRI of liver,uCSR could provide equivalent image quality in pa-tients with good breath holding and better image quality in patients with poor breath holding compared with quick3D.

关键词

光梭径向采集技术/自由呼吸/磁共振成像/图像质量

Key words

United compressed sensing with radial acquisition/Free breathing/Magnetic resonance imaging/Image quality

分类

医药卫生

引用本文复制引用

张宇,邓和平,何长久,杨学刚,胡仕北,周鹏..光梭径向采集技术和三维容积内插快速扰相序列在MRI肝脏增强扫描中的图像质量比较[J].肿瘤预防与治疗,2024,37(6):492-498,7.

基金项目

This study was supported by grants from Science and Technology Department of Sichuan Province(No.2021YFS0225)and Chengdu Science and Technology Bureau(No.2022-YF05-01811-SN). 四川省科技计划项目(编号:2021YFS0225) (No.2021YFS0225)

成都市科技计划项目(编号:2022-YF05-01811-SN) (编号:2022-YF05-01811-SN)

肿瘤预防与治疗

OACSTPCD

1674-0904

访问量0
|
下载量0
段落导航相关论文