Abstract
Liyuan hydropower station's main distribution system frequently shakes due to abnormal displacement sensors.By replacing two new displacement sensors and adjusting the zero position of the main electrical system,a quick switch guide vane test is conducted again.The results indicate that when the service life of the main displacement sensor approaches the service life of electronic components,there will be a certain degree of distortion in the linearity and sensitivity of the sensor,leading to abnormal feedback from the main displacement sensor of the governor,which in turn causes frequent jerking of the main displacement sensor.It is of great significance to ensure the safe,reliable,and stable operation of hydroelectric power plants over a long period of time by taking corresponding preventive measures.关键词
水电站/主配压阀/频繁抽动/原因分析/应急处置/防范措施Key words
hydropower station/main distribution valve/frequent twitching/cause analysis/emergency response/preventive measure分类