| 注册
首页|期刊导航|云南水力发电|大型水轮发电机调速器主配压阀频繁抽动问题分析及处理

大型水轮发电机调速器主配压阀频繁抽动问题分析及处理

耿晓育 刘照友 张俊杰

云南水力发电2024,Vol.40Issue(6):30-32,3.
云南水力发电2024,Vol.40Issue(6):30-32,3.DOI:10.3969/j.issn.1006-3951.2024.06.012

大型水轮发电机调速器主配压阀频繁抽动问题分析及处理

Analysis and Treatment of Frequent Pulling of the Main Distribution Valve in the Governor of Large Hydroelectric Generator

耿晓育 1刘照友 1张俊杰1

作者信息

  • 1. 云南华电金沙江中游水电开发有限公司梨园发电分公司,云南 丽江 674100
  • 折叠

摘要

Abstract

Liyuan hydropower station's main distribution system frequently shakes due to abnormal displacement sensors.By replacing two new displacement sensors and adjusting the zero position of the main electrical system,a quick switch guide vane test is conducted again.The results indicate that when the service life of the main displacement sensor approaches the service life of electronic components,there will be a certain degree of distortion in the linearity and sensitivity of the sensor,leading to abnormal feedback from the main displacement sensor of the governor,which in turn causes frequent jerking of the main displacement sensor.It is of great significance to ensure the safe,reliable,and stable operation of hydroelectric power plants over a long period of time by taking corresponding preventive measures.

关键词

水电站/主配压阀/频繁抽动/原因分析/应急处置/防范措施

Key words

hydropower station/main distribution valve/frequent twitching/cause analysis/emergency response/preventive measure

分类

建筑与水利

引用本文复制引用

耿晓育,刘照友,张俊杰..大型水轮发电机调速器主配压阀频繁抽动问题分析及处理[J].云南水力发电,2024,40(6):30-32,3.

云南水力发电

1006-3951

访问量0
|
下载量0
段落导航相关论文