|国家科技期刊平台
首页|期刊导航|中国内镜杂志|柔性臂消化内镜手术机器人在食管内镜黏膜下剥离术中的应用效果

柔性臂消化内镜手术机器人在食管内镜黏膜下剥离术中的应用效果OACSTPCD

Application of flexible auxiliary single-arm transluminal endoscopic robot in esophageal endoscopic submucosal dissection

中文摘要英文摘要

目的 比较柔性臂消化内镜手术机器人(FASTER)辅助食管内镜黏膜下剥离术(ESD)和传统食管ESD的临床效果,以探索更安全、高效的ESD手术方法.方法 分别采用FASTER辅助ESD和传统ESD方法在离体猪食管模型中进行手术操作.对比分析两组手术总时间、ESD时间、直视剥离率、整体切除率和并发症发生率的差异.结果 FASTER辅助ESD组的手术总时间[(19.2±2.9)和(28.9±8.2)min]和ESD时间[(13.0±2.9)和(21.6±8.3)min]明显短于传统ESD组,差异均有统计学意义(P<0.01);直视剥离率明显高于传统ESD组(96.2%和65.4%),差异有统计学意义(P=0.014);肌层损伤率明显低于传统ESD组(19.2%和69.2%),差异有统计学意义(P<0.01).两组完整切除率和穿孔率比较,差异均无统计学意义(P>0.05).这些优势在食管非重力位病变中更加明显.结论 FASTER辅助下的食管ESD较传统ESD更加安全和高效.

Objective To compare the efficacy of endoscopic submucosal dissection(ESD)using the flexible auxiliary single-arm transluminal endoscopic robot(FASTER)with that of the traditional technique,and explore a safer and more efficient ESD operation method.Methods FASTER-assisted ESD and traditional ESD were used to operate in the isolated pig esophagus model.The differences of total procedure time,ESD time,the rate of direct-vision dissection,complete en bloc resection and complication rate between the two groups were compared and analyzed.Results The total procedure time[(19.2±2.9)and(28.9±8.2)min]and ESD time[(13.0±2.9)and(21.6±8.3)min]were significantly shorter in FASTER-assisted ESD group than those in traditional ESD group,the differences were statistically significant(P<0.01);The rate of direct-vision dissection was significantly higher than that of the traditional ESD(96.2%and 65.4%),the difference was statistically significant(P=0.014).Muscle layer injury rate was significantly lower than of the traditional group(19.2%and 69.2%),the difference was statistically significant(P<0.01).There was no significant difference in complete en bloc resection rate and perforation rate between the two groups(P>0.05).These advantages were more apparent in esophageal non-gravity lesions.Conclusion Esophageal ESD assisted by FASTER is safer and more efficient than traditional ESD.

李清敏;张瑞昕;李茂生;季锐

山东大学齐鲁医院 消化内科,山东 济南 250012

临床医学

柔性臂消化内镜手术机器人(FASTER)传统手术内镜黏膜下剥离术(ESD)食管

flexible auxiliary single-arm transluminal endoscopic robot(FASTER)traditional surgeryendoscopic submucosal dissection(ESD)esophagus

《中国内镜杂志》 2024 (006)

17-22 / 6

泰山学者青年专家经费资助(No:tsqn202312333)

10.12235/E20240089