| 注册
首页|期刊导航|东北电力技术|300 MW四角切圆锅炉再循环烟气对蒸汽温度影响试验研究

300 MW四角切圆锅炉再循环烟气对蒸汽温度影响试验研究

黄实 杨兆林 赵阳 宋扬 孙熙

东北电力技术2024,Vol.45Issue(6):35-38,4.
东北电力技术2024,Vol.45Issue(6):35-38,4.

300 MW四角切圆锅炉再循环烟气对蒸汽温度影响试验研究

Experimental Research on Effect of Recirculation Flue Gas on Steam Temperature in 300 MW Quadrangle Tangential Boiler

黄实 1杨兆林 1赵阳 2宋扬 1孙熙1

作者信息

  • 1. 国家电投集团东北电力有限公司抚顺热电分公司,辽宁 抚顺 113005
  • 2. 辽宁东科电力有限公司,辽宁 沈阳 110179
  • 折叠

摘要

Abstract

In order to alleviate the problem of low load working condition main steam and reheat steam temperatures low in a 300 MW quadrangle tangential boiler,it carries out experimental research on the effect of recycled flue gas on steam temperature.The results show that the recycled flue gas is mainly affected by boiler combustion stability,heating surface wall temperature,margin of desuperheating water regulation,and exhaust gas temperature.After the flue gas recirculation system putting into operation under low load conditions,the main steam temperature and reheat steam temperature can be increased,and the inlet flue gas temperature of the denitrification system increases.Not only does it help to reduce the heat consumption rate and net coal consumption rate,improve the economic efficiency of low load operation of the unit,but it also helps to avoid the corrosion problem of the last stage blades of the steam turbine,and reduce equipment maintenance costs.

关键词

低负荷/蒸汽温度/供电煤耗

Key words

low load/steam temperature/net coal consumption rate

分类

信息技术与安全科学

引用本文复制引用

黄实,杨兆林,赵阳,宋扬,孙熙..300 MW四角切圆锅炉再循环烟气对蒸汽温度影响试验研究[J].东北电力技术,2024,45(6):35-38,4.

东北电力技术

1004-7913

访问量0
|
下载量0
段落导航相关论文