| 注册
首页|期刊导航|实验动物与比较医学|1470 nm半导体激光对离体动物组织的汽化消融、切割和凝固作用

1470 nm半导体激光对离体动物组织的汽化消融、切割和凝固作用

郑国 潘永明 黄俊杰 张辉 郁晨 陈民利 徐庆丰 黄恒

实验动物与比较医学2024,Vol.44Issue(3):279-288,10.
实验动物与比较医学2024,Vol.44Issue(3):279-288,10.DOI:10.12300/j.issn.1674-5817.2023.161

1470 nm半导体激光对离体动物组织的汽化消融、切割和凝固作用

Effects of 1470 nm Semiconductor Laser on Vaporization Ablation,Cutting,and Coagulation in Ex Vivo Animal Tissue

郑国 1潘永明 2黄俊杰 2张辉 1郁晨 3陈民利 2徐庆丰 1黄恒1

作者信息

  • 1. 合肥大族科瑞达激光设备有限公司,合肥 230088
  • 2. 浙江中医药大学动物实验研究中心/比较医学研究所,杭州 310053||杭州利孚泰生物科技有限公司,杭州 310051
  • 3. 杭州利孚泰生物科技有限公司,杭州 310051
  • 折叠

摘要

Abstract

Objective To observe the effects of a 1 470 nm semiconductor laser on vaporization cutting,coagulation,and thermal injury of ex vivo animal tissues,aiming to explore the feasibility of its application in the treatment of benign prostatic hyperplasia.Methods The experimental group and control group were treated with HANS-D1 and ML-DD01FI 1 470 nm semiconductor laser therapy equipment,respectively.Fresh ex vivo pig bladder tissue was exposed to lasers with the optical fiber placed at distances of 0.5 cm and 1 cm from the tissue for 5 s.The effects of layers at powers of 60,90,120,150,and 160 W on tissue injury were observed.Ex vivo dog prostate and pig kidney tissues were used for vaporization ablation and cutting to observe the effects of lasers at the same power levels on tissue vaporization and cutting thermal injury.Additionally,in coagulation mode,the effects of 30,40,and 50 W semiconductor lasers on tissue coagulation were observed after irradiating ex vivo pig kidney tissue for 5,10,and 15 seconds.Results When the optical fiber was placed 1 cm away from the tissue,the 1 470 nm semiconductor lasers did not cause accidental damage to adjacent normal bladder tissue.However,at a distance of 0.5 cm,the 120 W,150 W,or 160 W lasers caused slight damage to the bladder tissue.In addition,with the increase in output power,the vaporization ablation efficiency of 60-160 W lasers on dog prostate tissue gradually increased,showing a good linear correlation between vaporization volume and total energy consumption(P<0.001).Histopathological HE staining results indicated that the coagulation layer thickness in the experimental group was 292.20-309.98 μm,and the vaporization layer depth was 1.49-4.52 mm.In the control group,the coagulation layer thickness was 289.91-303.53 μm,and the vaporization layer depth was 1.88-4.43 mm.There was no significant difference between the two groups(P>0.05).Moreover,when performing vaporization cutting on ex vivo pig kidney tissue with a cross-sectional area of 1 cm2,the efficiency of vaporization cutting by the 60-160 W 1 470 nm semiconductor lasers increased with the increase in output power(P<0.05).The coagulated layer thickness in the experimental group was 496.04-514.47 μm,while that in the control group was 489.39-518.53 μm.Additionally,in coagulation mode,when ex vivo pig kidney tissue was irradiated for 5,10,and 15 s with 30,40,and 50 W semiconductor lasers,the coagulation diameter,groove depth,and coagulation efficiency gradually increased with the increase in laser output power(P<0.05).The coagulation layer thickness in the experimental group and control group was 399.10-449.98 μm and 392.97-447.65 μm,respectively,and the vaporization layer depth was 3.05-7.09 mm and 2.70-7.14 mm,respectively.There was no significant difference between the two groups(P>0.05).Conclusion The 1 470 nm semiconductor laser shows good vaporization ablation,cutting,and coagulation effect on ex vivo tissues,with a good linear correlation between the effect and the output energy.

关键词

前列腺增生/1470nm半导体激光/汽化切割/凝固/热损伤/离体动物组织

Key words

Benign prostatic hyperplasia/1 470 nm semiconductor laser/Vaporization cutting/Coagulation/Thermal injury/Ex vivo animal tissues

分类

医药卫生

引用本文复制引用

郑国,潘永明,黄俊杰,张辉,郁晨,陈民利,徐庆丰,黄恒..1470 nm半导体激光对离体动物组织的汽化消融、切割和凝固作用[J].实验动物与比较医学,2024,44(3):279-288,10.

实验动物与比较医学

OACSTPCD

1674-5817

访问量4
|
下载量0
段落导航相关论文