| 注册
首页|期刊导航|中国医疗设备|对用于肺部自适应放疗的合成CT影像质量的对比研究

对用于肺部自适应放疗的合成CT影像质量的对比研究

郑子龙 苏斌 钱呈 魏环海 陈童 赵瑞峰

中国医疗设备2024,Vol.39Issue(7):42-48,7.
中国医疗设备2024,Vol.39Issue(7):42-48,7.DOI:10.3969/j.issn.1674-1633.2024.07.007

对用于肺部自适应放疗的合成CT影像质量的对比研究

Comparative Study on the Quality of Synthetic CT Images Used in Adaptive Radiation Therapy for Lung

郑子龙 1苏斌 1钱呈 1魏环海 1陈童 1赵瑞峰1

作者信息

  • 1. 同济大学附属上海市肺科医院 放疗科,上海 200433
  • 折叠

摘要

Abstract

Objective To evaluate the image quality of synthetic CT(sCT)with different cone beam CT(CBCT)scanning modes based on Velocity software.Methods 4D-CT simulation was performed for the CIRS lung phantom by setting the regular respiratory motion pattern.The treatment planning was completed on the average intensity projection CT,that was the planning CT(pCT),which was then transfered to the TrueBeam linac to realize 3D-CBCT and 4D-CBCT scanning and image reconstruction respectively.Then the corresponding sCT was generated based on Velocity software.Results The sCT images preserved the fine structures of the reference pCT.There was a strong correlation between the two image contours,and all Dice similarity coefficients were more than 0.85.Through direct comparison,it could be seen that the artifacts of sCT images were significantly reduced compared with the corresponding CBCT images.The CT values of different regions of interest in sCT3D/sCT4D images were significantly lower,and the noise of sCT was less.For sCT,the average CT values percentage difference for sCT3D images was 7.68%,and the average CT values percentage difference for sCT4D images was 4.65% .Compared with 3D-CBCT,the CT value of sCT images obtained based on 4D-CBCT was significantly improved.Conclusion Under constant breathing pattern,the image quality of sCT corresponding to different CBCT generated from Velocity is comparable to that of pCT,respiratory-correlated image guidance is more clinically valuable in radiotherapy for lung cancer patients.

关键词

图像引导放疗/四维CT/合成CT/图像质量评估/自适应放疗

Key words

image guided radiotherapy/four dimensional CT/synthetic CT/image quality assessment/adaptive radiation therapy

分类

医药卫生

引用本文复制引用

郑子龙,苏斌,钱呈,魏环海,陈童,赵瑞峰..对用于肺部自适应放疗的合成CT影像质量的对比研究[J].中国医疗设备,2024,39(7):42-48,7.

基金项目

上海市"科技创新行动计划"生物医药领域科技支撑项目(18441905600). (18441905600)

中国医疗设备

OACSTPCD

1674-1633

访问量0
|
下载量0
段落导航相关论文