冷却塔-内嵌管式相变屋面复合降温系统的性能研究

逯焕杰 陈晓明 吴智昊 邱金友

储能科学与技术2024,Vol.13Issue(7):2435-2446,12.
储能科学与技术2024,Vol.13Issue(7):2435-2446,12.DOI:10.19799/j.cnki.2095-4239.2024.0010

冷却塔-内嵌管式相变屋面复合降温系统的性能研究

Performance of an integrated cooling system combining a cooling tower and a pipe-embedded phase-change-material slab roof

逯焕杰 1陈晓明 1吴智昊 1邱金友1

作者信息

  • 1. 福建理工大学生态环境与城市建设学院,福建 福州 350118
  • 折叠

摘要

Abstract

To enhance the performance of phase-change-material(PCM)slab roofs,this study proposes an integrated cooling system combining a cooling tower with a pipe-embedded PCM slab roof.Further,leveraging the enthalpy method,the study establishes a computational heat transfer model of the developed integrated cooling system.Subsequently,the thermal performance and energy-saving potential of a similar system in Fuzhou city,China,are numerically investigated.Furthermore,the impacts of the phase-change temperature and thermal conductivity of the PCM and the pipe interval are explored,and the developed system is compared with a traditional PCM slab roof without embedded pipes.The results reveal that higher phase-change temperatures of the PCM lead to more significant solidification of the PCM within the integrated cooling system.However,with increasing phase-change temperatures of the PCM,the utilization rate of the PCM's heat of fusion within the system initially increases and subsequently decreases.Specifically,increasing the phase-change temperature of the PCM from 35℃ to 41℃ leads to a corresponding rise in the accumulated cooling load of the roof from 383 kJ/m2 to 400 kJ/m2,presenting an increase of 4.4%.Furthermore,higher thermal conductivities of the PCM and narrower pipe intervals improve the utilization rate of the PCM's heat of fusion within the integrated cooling system compared to that within traditional PCM slab roofs without embedded pipes.Specifically,increasing the thermal conductivity of the PCM from 0.2 W/(m·K)to 0.8 W/(m·K)boosts the utilization rate of the PCM's heat of fusion and the accumulated cooling load of the roof by 36.3%and 5.1%,respectively.Conversely,the corresponding values of the traditional PCM slab roof increase by only 33.1%and 6.3%,respectively.Moreover,when the pipe interval is decreased from 500 mm to 100 mm,the utilization rate of the PCM's heat of fusion in the integrated cooling system surpasses that in the traditional PCM slab roof by 2.7%—16.3%.Concurrently,the reduction in the accumulated cooling load of the roof increases from 3.8%to 10.9%.Overall,these findings demonstrate the potential of integrated cooling systems in promoting building energy savings and contributing toward the realization of dual-carbon goals.

关键词

相变屋面/冷却塔/内嵌管/蓄冷/建筑节能

Key words

PCM slab roof/cooling tower/pipe-embedded/cooling energy storage/building energy saving

分类

能源科技

引用本文复制引用

逯焕杰,陈晓明,吴智昊,邱金友..冷却塔-内嵌管式相变屋面复合降温系统的性能研究[J].储能科学与技术,2024,13(7):2435-2446,12.

基金项目

福建省自然科学基金(2023J01934,2021J011055),福建理工大学科研启动基金(GY-Z18005). (2023J01934,2021J011055)

储能科学与技术

OA北大核心CSTPCD

2095-4239

访问量0
|
下载量0
段落导航相关论文