摘要

Abstract

The energy consumption of university catering building is particularly prominent and there are few related research papers.In this paper,the catering building in Taiyuan University of Technology located in cold areas is taken as the main research object.Through testing and analyz-ing the indoor and outdoor thermal environment of the catering building in Taiyuan University of Technology in winter,the standard equivalent temperature method is selected to evaluate the thermal comfort of the catering building in Taiyuan University of Technology in winter.Through the establishment of computer models and standard simulation methods,according to the analysis re-sults,the paper puts forward suggestions for trans-formation.

关键词

太原市/高校餐饮建筑/热环境/测试/优化

Key words

Taiyuan City/university catering building/thermal environment/test/optimization