电力勘测设计Issue(7):42-46,71,6.DOI:10.13500/j.dlkcsj.issn1671-9913.2024.07.009
燃煤电厂新增碳捕集和储存装置布置方案研究
Research on the Layout Scheme of the Newly Added Carbon Capture and Storage Device in Coal-Fired Power Plant
唐磊 1张志军 1王志勇 1曾芳1
作者信息
- 1. 中国能源建设集团湖南省电力设计院有限公司,湖南 长沙 410007
- 折叠
摘要
Abstract
At present,there is a lack of research on the layout of the newly added carbon capture and storage devices in the existing power plants in China,which is likely to cause a large amount of new land occupation,difficult pipeline layout,and affect the selection of related equipment,resulting in an increase in investment.Based on the existing plant conditions and characteristics of a 2×350 MW power plant with indirect dry cooling tower of three incorporate towers system,two layout schemes for adding a 200,000-ton/year carbon capture and storage device were proposed and compared technically and economically.It is recommended to make full use of the space in the indirect dry cooling tower to arrange carbon capture and storage devices.The scheme has advantages in technological process,environmental protection,land occupation,cost,etc.However,attention should be paid to the reasonable arrangement of the construction and installation plan in the indirect dry cooling tower and the calculation of the impact of the newly added carbon capture facilities in the indirect dry cooling tower on the performance of the existing indirect dry cooling tower.关键词
碳捕集及储存装置/间接空冷塔/三塔合一/布置方案/造价Key words
carbon capture and storage device/indirect dry cooling tower/three incorporate towers/layout plan/cost分类
信息技术与安全科学引用本文复制引用
唐磊,张志军,王志勇,曾芳..燃煤电厂新增碳捕集和储存装置布置方案研究[J].电力勘测设计,2024,(7):42-46,71,6.