| 注册
首页|期刊导航|建筑结构学报|装配式冷弯薄壁型钢-泡沫混凝土组合墙体抗震性能试验研究

装配式冷弯薄壁型钢-泡沫混凝土组合墙体抗震性能试验研究

彭志明 陈忠范 徐志峰 黄宇浩 罗漪

建筑结构学报2024,Vol.45Issue(7):177-188,12.
建筑结构学报2024,Vol.45Issue(7):177-188,12.DOI:10.14006/j.jzjgxb.2023.0248

装配式冷弯薄壁型钢-泡沫混凝土组合墙体抗震性能试验研究

Experimental study on seismic behavior of prefabricated cold-formed thin-walled steel-foam concrete composite walls

彭志明 1陈忠范 1徐志峰 2黄宇浩 1罗漪3

作者信息

  • 1. 东南大学 中国-巴基斯坦重大基础设施智慧防灾"一带一路"联合实验室,江苏南京 211189||东南大学土木工程学院,江苏南京 211189
  • 2. 山东科技大学土木工程与建筑学院,山东青岛 266590
  • 3. 华侨大学福建省智慧基础设施与监测重点实验室,福建厦门 361021
  • 折叠

摘要

Abstract

In order to promote the development of cold-formed thin-walled steel building structure system and improve its assembly ratio,three dry assembly forms of connection between the flanges and webs of the walls were proposed.To study the seismic behavior of the composite walls,three different prefabricated cold-formed thin-walled steel-foam concrete composite wall specimens and one cast-in-place wall specimen were tested under low-cycle reciprocating load.The failure mode,bearing capacity,lateral stiffness,energy dissipation and ductility of specimens were analyzed.The reliability of the three types of dry connection and the differences in seismic performance of the walls with different assembly forms were studied.The results show that the failure of the wall is mainly concentrated in the web pier,the wall panels between the columns and the foam concrete filled inside appear crossed oblique cracks,the horizontal braces are subjected to local buckling,and only a few horizontal and vertical cracks appear at the bottom of the flanges of the wall pier.The three dry connections are safe and reliable,and the components fail before the joint.Compared with the cast-in-place counterpart,the bearing capacity and initial stiffness of the assembly specimens are lower,but the deformation and energy dissipation capabilities are higher.Compared with the web spliced wall,the peak load,initial stiffness and total energy dissipation of the tensile connection wall are increased by 36.5%,15.0%and 12.5%,respectively,and the peak load and total energy dissipation of the L-joint wall are increased by 22.8%and 54.5%,respectively,the initial stiffness is reduced by 21.5%.Considering the seismic performance,transportation condition and construction difficulty of the three assembly forms comprehensively,the assembly form of L-shaped connector is preferred for engineering practice.Based on the principle of superposition,the lateral stiffness of the prefabricated composite wall was deduced,and the accuracy of the calculation method was verified.

关键词

装配式组合墙体/冷弯薄壁型钢/泡沫混凝土/拟静力试验/抗震性能

Key words

prefabricated composite wall/cold-formed thin-walled steel/foam concrete/pseudo-static test/seismic performance

分类

建筑与水利

引用本文复制引用

彭志明,陈忠范,徐志峰,黄宇浩,罗漪..装配式冷弯薄壁型钢-泡沫混凝土组合墙体抗震性能试验研究[J].建筑结构学报,2024,45(7):177-188,12.

基金项目

国家自然科学基金面上项目(52078120). (52078120)

建筑结构学报

OA北大核心CSTPCD

1000-6869

访问量0
|
下载量0
段落导航相关论文