液压与气动2024,Vol.48Issue(7):79-85,7.DOI:10.11832/j.issn.1000-4858.2024.07.009
膜阀微流道液流脉动消减性能
Flow Pulsation Reduction Performance in Microfluidic Channel of Membrane Valve
摘要
Abstract
Propose a method of actively reducing liquid flow pulsation in liquid microchannels of microfluidic chips using on-chip membrane valves.Taking the valve chamber accumulator and valve chamber damping hole as the research objects,the ANSYS Fluent UDF custom simulation method was used to study the reduction performance of liquid flow pulsation in the micro channel of the membrane valve.Results shown that the reduction effect of different structural reduction elements is different,and the reduction effect varies with the number of membrane valves.Based on the working principle of pulsation reduction elements,liquid flow pulsation reduction experiments were carried out.The experiment shows that the active reduction method of liquid flow pulsation in microfluidic channel based on membrane valves is an effective verification of the rationality of the liquid flow reduction element in microfluidic channel based on membrane valves,the correctness of the theoretical model,and the feasibility of specific applications.It provides theoretical guidance and technical support for precise control technology of micro liquid flow rate.关键词
微流控芯片/片上膜阀/复合控制/脉动消减/出口流量Key words
microfluidic chip/on-chip membrane valve/composite control/pulsation reduction/outlet flow rate分类
机械工程引用本文复制引用
刘旭玲,薄乐,张钰松,刘威,张开贻,邵景干..膜阀微流道液流脉动消减性能[J].液压与气动,2024,48(7):79-85,7.基金项目
国家自然科学基金(52005453) (52005453)
河南省科技攻关项目(232102320056) (232102320056)
河南省交通运输厅科技项目(2020J1,2020J2) (2020J1,2020J2)