摘要
Abstract
Aiming at the problem of blood leakage from internal fistula of patients who received dialysis during treatment,the existing Bluetooth technique was applied to design a circuit diagram.A movable monitoring device of blood leakage from internal fistula was designed,and an intelligent alarm mode for the blood leakage from internal fistula was established,which could real-timely remind the blood leakage from internal fistula.The device used the technique of moisture absorption cotton patch and real-time reminder device to supplement the design defects and related treatment schemes of the existing hemodialysis machine,which could realize the safe and effective management for blood leakage from internal fistula,and can avoid the occurrence of adverse events caused by delayed treatment.关键词
可移动/内瘘/渗血/湿敏传感器/监测Key words
Portability/Internal fistula/Blood leakage/Humidity sensor/Monitor分类
基础医学引用本文复制引用
蒋忠伟,严春华,王秦..一种可移动防止内瘘渗血监测装置的设计[J].中国医学装备,2024,21(7):188-191,4.基金项目
2022年度上海市奉贤区科学技术发展基金项目(20211812) Fund Project:Monitoring Fund Project:Shanghai Fengxian District Science and Technology Development Fund Project in 2022(20211812) (20211812)