| 注册
首页|期刊导航|水利水电技术(中英文)|灯泡贯流式机组水导轴承振动评估

灯泡贯流式机组水导轴承振动评估

付亮 王治国 王佩

水利水电技术(中英文)2024,Vol.55Issue(7):104-113,10.
水利水电技术(中英文)2024,Vol.55Issue(7):104-113,10.DOI:10.13928/j.cnki.wrahe.2024.07.009

灯泡贯流式机组水导轴承振动评估

Vibration evaluation of water guide bearing of bulb tubular unit

付亮 1王治国 2王佩1

作者信息

  • 1. 湖南五凌电力科技有限公司,湖南长沙 410007
  • 2. 哈尔滨大电机研究所,黑龙江哈尔滨 150040
  • 折叠

摘要

Abstract

[Objective]For the water guide bearing with fan-shaped support structure,the horizontal structural stiffness is insuffi-cient,resulting in a large vibration value.It is necessary to evaluate the vibration of the water guide bearing and determine a rea-sonable vibration limit to ensure the safety and stability of the unit.[Methods]The vibration of the water guide bearing of the same type of bulb tubular unit is statistically analyzed.The finite element calculation of the water guide bearing is carried out.The field test of vibration and dynamic stress is carried out.The correlation between dynamic stress and vibration is analyzed.The fatigue characteristics of the water guide bearing structure are evaluated to determine the reasonable vibration limit.[Results]The result show that the median of the horizontal vibration statistical sample of the water guide bearing is 131.6 μm,according to the standard requirements,1.6 times the median value of 200.0 µm is taken as the reference value of the vibration limit.Based on the finite element analysis and actual measurement of the water guide bearing in Lingjintan Power Plant,the max-imum static stress of the water guide bearing is 33.8 MPa,which is far less than the allowable stress requirement,the maximum horizontal vibration peak value of the water guide bearing under test conditions is 91.0 µm,and the maximum dynamic stress peak value of the sector plate is 1.4 MPa.[Conclusion]The result show that:The horizontal vibration of water guide bearing of bulb tubular units increases with the increase of the active power of the unit,the main frequencies of vibration and dynamic stress are the rotation frequency of the unit and the frequency doubling of blade blades,the vibration amplitude has a good linear rela-tionship with the dynamic stress amplitude,and the dynamic stress at a vibration amplitude of 200.0 µm can be predicted by lin-ear fitting.According to the ultimate dynamic stress and static stress obtained by finite element analysis,the fatigue life and damage coefficient of water guide bearing support structure can be obtained by S-N curve,and the result show that it can meet the requirements of service life cycle.

关键词

灯泡贯流式机组/水导轴承/振动评估/疲劳分析/影响因素

Key words

bulb tubular unit/water guide bearing/vibration assessment/fatigue analysis/influence factor

分类

能源科技

引用本文复制引用

付亮,王治国,王佩..灯泡贯流式机组水导轴承振动评估[J].水利水电技术(中英文),2024,55(7):104-113,10.

基金项目

国家科技支撑计划项目(2012BAF12B16-1) (2012BAF12B16-1)

黑龙江省自然科学基金项目(ZD2020E002) (ZD2020E002)

湖南省自然科学基金项目(2024JJ9169) (2024JJ9169)