实时动态血糖监测系统在妊娠糖尿病血糖波动中的应用OACSTPCD
Application of real-time dynamic blood glucose monitoring system in blood glucose fluctuation of pregnant women with diabetes
目的:探讨实时动态血糖监测系统(CGMS)在妊娠糖尿病血糖波动监测中的应用价值.方法:前瞻性选取2022年9月至2023年12月收治的97例妊娠糖尿病患者,分为观察组(n=49,采用CGMS监测)和对照组(n=48,常规血糖仪监测),均接受胰岛素治疗.对比空腹血糖、餐后 2h血糖、症状控制、低血糖情况及满意度.结果:治疗后,观察组空腹及餐后 2h血糖均低于对照组(P<0.05),且血糖控制、症状缓解及住院时间更短.此外,观察组低血糖发生率更低(P<0.05),持续时间更短,治疗满意度更高(P<0.05).结论:CGMS 系统精准监测孕妇血糖,提升治疗效果与满意度,预防不良事件.
Objective:To investigate the value of real-time continuous glucose monitoring system(CGMS)in monitoring blood glucose fluctuation in gestational diabetes mellitus(GDM).Methods:97 patients with gestational diabetes admitted from September 2022 to December 2023 were prospectively selected and divided into the observation group(n=49,monitored by CGMS)and the control group(n=48,monitored by conventional blood glucose meter),all of whom received insulin treatment.Compare fasting blood glucose,2-hour postprandial blood glucose,symptom control,hypoglycemia status,and satisfaction.Results:After treatment,the fasting and 2-hour postprandial blood glucose levels in the observation group were lower(P<0.05),and blood glucose control,symptom relief,and hospital stay were shorter.In addition,the observation group had a lower incidence of hypoglycemia(P<0.05),shorter duration,and higher treatment satisfaction(P<0.05).Conclusions:The CGMS system accurately monitors pregnant women's blood sugar,improves treatment effectiveness and satisfaction,and prevents adverse events.
周红;许荣华;朱增秀;张乙敏
安徽省妇女儿童医学中心(合肥市妇幼保健院)产科,安徽合肥 230001安徽省妇女儿童医学中心(合肥市妇幼保健院)护理部,安徽合肥 230001安徽省妇女儿童医学中心(合肥市妇幼保健院)产科,安徽合肥 230001安徽省妇女儿童医学中心(合肥市妇幼保健院)产科,安徽合肥 230001
CGMS系统妊娠糖尿病血糖波动胰岛素低血糖
CGMS systemGestational diabetes mellitusBlood glucose fluctuationInsulinHypoglycemia
《现代科学仪器》 2024 (4)
71-74,4