能源工程2024,Vol.44Issue(4):65-68,4.DOI:10.16189/j.nygc.2024.04.011
协同烟羽治理烟气余热利用系统的节能分析
Energy saving analysis of flue gas waste heat recoverysystem cooperative with plume control
许一凡 1蔡昂 1宁旭 1隰刚 1张晓辉 1李准 1梁秀进 2李存文2
作者信息
- 1. 河北华电石家庄鹿华热电有限公司,河北 石家庄 050200
- 2. 华电电力科学研究院有限公司,浙江 杭州 310030
- 折叠
摘要
Abstract
To alleviate white smoke phenomenon in chimney,a coal-fired 330MW power unit was equipped with a condensation-re-heat plume control system equipped and turn into a pure environment protective unit,which contains flue gas cooler,gas heater and condenser.In demand of plume control and energy saving,a cooperative waste energy recovery retrofit was carried out,which includes:(1)Add plate heat exchanger A,by which condensate water of low-pressure heater system is heated by hot medium water from cooler.(2)Add plate heat exchanger B,by which returned water from heat supply network is heated by hot medium water from cooler.(3)Add plate heat exchanger C,through which,water replenishment of heat supply network has been heated by circulating cooling water from flue gas condenser.Then extraction steam of JD3 from low-pressure heater system have been reduced because of A and heating extraction steam have been reduced because of operation of B and C during heating period.Performance test results show that the added waste heat recovery has reduced coal consumption of the unit power generation 1.09 g/(kW·h)during non-heat-ing period and 2.30 g/((kW·h)during heating period separately.关键词
烟羽治理/冷凝-再热/协同余热利用/节能降耗Key words
plume control/condense-reheat/collaborative waste heat recovery,coal consumption decrease分类
能源科技引用本文复制引用
许一凡,蔡昂,宁旭,隰刚,张晓辉,李准,梁秀进,李存文..协同烟羽治理烟气余热利用系统的节能分析[J].能源工程,2024,44(4):65-68,4.