科技创新与应用2024,Vol.14Issue(26):142-145,4.DOI:10.19981/j.CN23-1581/G3.2024.26.031
HXD1型交流电力机车高速电磁阀故障原因分析及改进措施
史衍可1
作者信息
- 1. 中铁十五局集团有限公司朔黄铁路运输处,河北 肃宁 062350
- 折叠
摘要
Abstract
The failure of high-speed solenoid valve in braking system brings serious hidden danger to the operation safety of heavy haul train.This paper analyzes the causes of high-speed solenoid valve failure of HXD1 AC electric locomotive;and aiming at improving the performance of high-speed solenoid valve grease,increasing the filter screens for high-speed solenoid valves,adjusting the PWM control cycle,and using a new cut-off high-speed solenoid valve,this paper puts forward improvement measures and emergency measures,greatly reducing the safety risks caused by the failure of high-speed solenoid valve;and the effect of on-site verification proves remarkable,thereby effectively ensures the operation safety of 10 000-ton and 20 000-ton heavy-haul trains.关键词
HXD1型交流机车/高速电磁阀/卡滞/257YV/258YV/PWM板/润滑油脂Key words
HXD1 AC locomotive/high-speed solenoid valve/stagnation/257YV/258YV/PWM board/lubricating grease分类
交通运输引用本文复制引用
史衍可..HXD1型交流电力机车高速电磁阀故障原因分析及改进措施[J].科技创新与应用,2024,14(26):142-145,4.