便携式呼出气冷凝液采集装置的设计

向安 汪莉 郭晏海 卢兹凡 周磊 纪奇峰 李远辙 汪钦 朱诗曼 彭婕 雷小英 李维娜

医疗卫生装备2024,Vol.45Issue(8):32-37,6.
医疗卫生装备2024,Vol.45Issue(8):32-37,6.DOI:10.19745/j.1003-8868.2024150

便携式呼出气冷凝液采集装置的设计

Design of portable collection device for exhaled breath condensate

向安 1汪莉 1郭晏海 1卢兹凡 1周磊 2纪奇峰 1李远辙 3汪钦 1朱诗曼 1彭婕 1雷小英 1李维娜1

作者信息

  • 1. 空军军医大学药学系,西安 710032
  • 2. 空军军医大学第一附属医院检验科,西安 710032
  • 3. 空军军医大学军事生物医学工程学系,西安 710032
  • 折叠

摘要

Abstract

Objective To develop a portable collection device of human exhaled breath condensate(EBC)based on natural breathing to meet the needs for rapid screening of human respiratory tract(especially lower respiratory tract)infections.Methods The device consisted of a refrigeration unit,a heat dissipation unit and a condensation unit.The refrigeration unit adopted a TES1-7102 thermoelectric Peltier cooler semiconductor as the refrigeration element;the heat dissipation unit was composed of a high thermal conductivity aluminum heat sink and a high-speed brushless cooling fan;the condensation unit was made up of a cold guide plate and a condenser,in which the cold guide plate was made of thin sheet of aluminum alloy,and the condenser was prepared by 3D printing technology and made of hydrophobic polylactic acid,with primary and secondary 2-stage guide grooves and an ultra-thin condensing surface.The performance of the device was verified in terms of cooling,thermal conductivity,condensation and human EBC collection and content analysis.Results Performance analysis showed that after refrigeration began the temperature difference between the condenser surface and the exhaled gas met the requirements of the condenser,and no obvious thermal resistance was found on the condensing surface so that large droplets could be formed rapidly and then be collected after the gas-liquid phase change of the exhaled gas on the condensing surface.Human EBC collection and content analysis indicated the device realized home self-collection of EBCs from people of all ages,and the concentrations of interleukins,C-reactive protein and other inflammation-related indexes and the pH value of the collected EBC samples were all correlated with respiratory infections in the subjects.Conclusion The device developed with easy operation avoids the discomfort of blowing collection and the risk of saliva contamination,and is worthy promoting for rapid diagnosis and dynamic monitoring of respiratory tract infection and other related diseases.[Chinese Medical Equipment Journal,2024,45(8):32-37]

关键词

呼出气冷凝液/呼出气冷凝液采集装置/冷凝器/呼吸道感染

Key words

exhaled breath condensate/portable collection device for exhaled breath condensate/condenser/respiratory tract infection

分类

医药卫生

引用本文复制引用

向安,汪莉,郭晏海,卢兹凡,周磊,纪奇峰,李远辙,汪钦,朱诗曼,彭婕,雷小英,李维娜..便携式呼出气冷凝液采集装置的设计[J].医疗卫生装备,2024,45(8):32-37,6.

基金项目

陕西省自然科学基金项目(2023-JC-YB-734) (2023-JC-YB-734)

军队科研项目(2020SWAQ06) (2020SWAQ06)

医疗卫生装备

OACSTPCD

1003-8868

访问量4
|
下载量0
段落导航相关论文