| 注册
首页|期刊导航|中国卒中杂志|上肢动作研究测试量表评定亚急性期缺血性卒中患者偏瘫侧上肢及手功能的信效度和敏感性研究

上肢动作研究测试量表评定亚急性期缺血性卒中患者偏瘫侧上肢及手功能的信效度和敏感性研究

吴娱倩 张玉梅 臧大维 范小伟 王安心 张晓丽 孟霞

中国卒中杂志2024,Vol.19Issue(8):915-923,9.
中国卒中杂志2024,Vol.19Issue(8):915-923,9.DOI:10.3969/j.issn.1673-5765.2024.08.009

上肢动作研究测试量表评定亚急性期缺血性卒中患者偏瘫侧上肢及手功能的信效度和敏感性研究

Study on the Reliability,Validity,and Sensitivity of Action Research Arm Test Scale in Evaluating the Function of Hemiplegic Upper Limb and Hand in Subacute Stage Ischemic Stroke Patients

吴娱倩 1张玉梅 1臧大维 2范小伟 3王安心 4张晓丽 4孟霞4

作者信息

  • 1. 北京 100070 首都医科大学附属北京天坛医院康复医学科
  • 2. 北京 100070 首都医科大学附属北京天坛医院康复医学科||国家神经系统疾病临床医学研究中心||首都医科大学附属北京天坛医院神经病学中心
  • 3. 首都医科大学附属北京天坛医院神经精神与临床心理科
  • 4. 国家神经系统疾病临床医学研究中心||首都医科大学附属北京天坛医院神经病学中心
  • 折叠

摘要

Abstract

Objective To evaluate the validity,reliability,and sensitivity of the action research arm test(AR AT)scale in evaluating the function of hemiplegic upper limb and hand in subacute stage ischemic stroke patients. Methods In this study,300 patients with ischemic stroke admitted to 17 hospitals including Beijing Tiantan Hospital,Capital Medical University from January 2020 to May 2022 were recruited.The ARAT scale was used to assess all the patients by two evaluators,independently.The Fugl-Meyer assessment-upper extremity(FMA-UE)scale was taken as the criterion.The Spearman correlation analysis and the confirmatory factor analysis were used to evaluate the criterion validity and construct validity of the ARAT scale,respectively.The Cronbach's α coefficient and intraclass correlation coefficient analysis were used to evaluate the internal reliability,sensitivity,and external reliability of the ARAT scale. Results With FMA-UE as the criterion,the FMA-UE total score was positively correlated with the ARAT total score(r=0.946,P<0.001).To evaluate the construct validity,the confirmatory factor analysis showed that the correlation coefficient between the factors ranged from 0.79 to 0.92,the overall fitting index of the model was x2/df=7.011,P=0.001,the comparative fit index=0.906,the incremental fix index=0.907,the normed fit index=0.895,and the root mean square error of approximation=0.055.The combined reliability values of each factor ranged from 0.964 to 0.983,and the average amount of variation of each factor ranged from 0.940 to 0.952.In the internal consistency test,the Cronbach's α coefficient of grade score was 0.987,and the Cronbach's αcoefficient ranged from 0.986 to 0.987 in the sensitivity analysis.In the external consistency test,the highest intraclass correlation coefficient between the two evaluators was 0.999,and the 95%CI was concentrated between 0.961 and 0.999. Conclusions ARAT scale has good criterion validity,construct validity,reliability,and sensitivity,which is suitable for evaluating the function of hemiplegic upper limb and hand in subacute stage ischemic stroke patients.

关键词

缺血性卒中/上肢功能/手功能/效标效度/结构效度/信度/敏感性/上肢动作研究测试量表

Key words

Ischemic stroke/Upper limb function/Hand function/Criterion validity/Construct validity/Reliability/Sensitivity/Action research arm test scale

分类

医药卫生

引用本文复制引用

吴娱倩,张玉梅,臧大维,范小伟,王安心,张晓丽,孟霞..上肢动作研究测试量表评定亚急性期缺血性卒中患者偏瘫侧上肢及手功能的信效度和敏感性研究[J].中国卒中杂志,2024,19(8):915-923,9.

基金项目

国家自然科学基金面上项目(82071295 ()

82072532) ()