基于GA-BP优化模型的红外CO分析仪温度补偿研究

邹永洺 王银辉 田富超

煤矿安全2024,Vol.55Issue(9):60-70,11.
煤矿安全2024,Vol.55Issue(9):60-70,11.DOI:10.13347/j.cnki.mkaq.20240569

基于GA-BP优化模型的红外CO分析仪温度补偿研究

Research on temperature compensation of infrared CO analyzer based on GA-BP optimization model

邹永洺 1王银辉 1田富超2

作者信息

  • 1. 煤炭科学研究总院,北京 100013||中煤科工集团沈阳研究院有限公司,辽宁 抚顺 113122||煤矿灾害防控全国重点实验室,辽宁 抚顺 113122
  • 2. 中煤科工集团沈阳研究院有限公司,辽宁 抚顺 113122||煤矿灾害防控全国重点实验室,辽宁 抚顺 113122
  • 折叠

摘要

Abstract

Spectral analysis is an important technical means for the quantitative analysis of coal mine gas.However,the portable in-frared gas sensor widely used at present is greatly affected by the ambient temperature in the field test process.In order to improve the analysis accuracy and applicability of the gas analyzer,we carry out theoretical analysis and experimental research around the ne-cessity of constant temperature heating of infrared gas analyzers,reasonable heating temperature range,and optimization model of test data error.Firstly,an experimental platform of infrared gas analyzer covering pre-temperature compensation,constant temperat-ure heating test,post-temperature compensation and different test environment temperature conditions is constructed,and the experi-mental steps as well as the corresponding analytical methods are proposed;secondly,in the ambient temperature of 25-45℃interval,the tested CO gas volume fraction is 800×10-6,through a lot of tests,it is found that the accuracy of CO gas analyzer is best when the heating temperature is 45℃,the test value is the closest to the true value of gas volume fraction.At the same time,CO(10×10-6-500×10-6)standard gas is selected for the accuracy test,and the absolute error of the calculated CO gas is only 0-9×10-6,which is better than the error range specified in the standard;then,setting the variable temperature environment of-15-45℃,the temperat-ure compensation verification of the heated CO gas sensor is carried out,the test results show that the lower the ambient temperature,the higher the volume fraction of the gas to be measured,the greater the sensor detection error,the maximum error can reach 110×10-6;based on this,the error analysis models of BP and GA-BP neural network are established,and the ambient temperature,test volume fraction and standard gas volume fraction are fused with the optimized model.It is found that MAE value obtained by GA-BP neural network model is reduced by 12.982 3×10-6 compared with BP neural network.The MSE and RMSE calculation res-ults also verify the stability and feasibility of GA-BP model in gas analysis.

关键词

CO分析仪/加热温度/温度补偿/GA-BP优化模型/误差分析

Key words

CO analyzer/heating temperature/temperature compensation/GA-BP optimization model/error analysis

分类

矿业与冶金

引用本文复制引用

邹永洺,王银辉,田富超..基于GA-BP优化模型的红外CO分析仪温度补偿研究[J].煤矿安全,2024,55(9):60-70,11.

基金项目

国家自然科学基金资助项目(52174229,52174230) (52174229,52174230)

国家重点研发计划资助项目(2023YFB3211000) (2023YFB3211000)

辽宁省自然科学基金资助项目(2023-MS-355,2021-KF-13-03) (2023-MS-355,2021-KF-13-03)