| 注册
首页|期刊导航|电力勘测设计|基于静力推覆分析的主厂房结构地震易损性研究

基于静力推覆分析的主厂房结构地震易损性研究

李庆文 胡扬 张雯

电力勘测设计Issue(9):63-68,6.
电力勘测设计Issue(9):63-68,6.DOI:10.13500/j.dlkcsj.issn1671-9913.2024.09.012

基于静力推覆分析的主厂房结构地震易损性研究

Research on Seismic Fragility of Main Building Based on Static Pushover Analysis

李庆文 1胡扬 2张雯1

作者信息

  • 1. 中国能源建设集团辽宁电力勘测设计院有限公司,辽宁 沈阳 110170
  • 2. 中国能源建设集团辽宁电力勘测设计院有限公司,辽宁 沈阳 110170||中国地震局工程力学研究所,黑龙江 哈尔滨 150080
  • 折叠

摘要

Abstract

SPO2IDA method approximately estimates the incremental dynamic analysis curves by the backbone line of static pushover,which is a parameter analysis method based on static pushover analysis.SPO2IDA method extracts information from the static pushover curve and produces the necessary statistical estimation of the limit states'responses.On the basis of SPO2IDA method,puts forward a seismic fragility analysis method based on static pushover analysis,and uses this method to analyze the seismic fragility of the main building structure of a thermal power plant,and obtains the fragility curves of the structure corresponding to four limit states,and compares the results with those of the seismic fragility analysis method based on incremental dynamic analysis.The research shows that the seismic fragility analysis results based on static pushover analysis can provide reasonable and reliable seismic fragility data of the main building.

关键词

主厂房/地震易损性/静力推覆/SPO2IDA方法/增量动力分析

Key words

main building/seismic fragility/static pushover/SPO2IDA method/incremental dynamic analysis

分类

信息技术与安全科学

引用本文复制引用

李庆文,胡扬,张雯..基于静力推覆分析的主厂房结构地震易损性研究[J].电力勘测设计,2024,(9):63-68,6.

电力勘测设计

1671-9913

访问量0
|
下载量0
段落导航相关论文