| 注册
首页|期刊导航|电力勘测设计|高效超超临界二次再热机组管道效率取值研究

高效超超临界二次再热机组管道效率取值研究

蒋健

电力勘测设计Issue(9):69-74,6.
电力勘测设计Issue(9):69-74,6.DOI:10.13500/j.dlkcsj.issn1671-9913.2024.09.013

高效超超临界二次再热机组管道效率取值研究

Research on the Value of Pipeline Efficiency of High-Efficiency Ultra-Supercritical Double-Reheat Unit

蒋健1

作者信息

  • 1. 中国电力工程顾问集团华东电力设计院有限公司,上海 200063
  • 折叠

摘要

Abstract

High-efficiency ultra-supercritical secondary reheat technology has become an frontier technology representative for the thermal power industry.Pipeline efficiency is one of the key factors affecting the thermo-economic performance of this technology.To study the reasonable value of pipeline efficiency for high-efficiency ultra-supercritical secondary reheat units,this paper takes the boundary conditions under THA conditions of a domestic 1 000 MW high-efficiency ultra-supercritical secondary reheat unit as an example,and adopts an anti-balance pipeline efficiency calculation scheme.The results show that the pipeline efficiency value can be increased from the conventional 99%to 99.5%,which can further improve the overall efficiency and performance of the unit.

关键词

高效超超临界/二次再热/管道效率/热经济性

Key words

high-efficiency ultra-supercritical/double reheat/pipeline efficiency/thermal economy

分类

信息技术与安全科学

引用本文复制引用

蒋健..高效超超临界二次再热机组管道效率取值研究[J].电力勘测设计,2024,(9):69-74,6.

电力勘测设计

1671-9913

访问量0
|
下载量0
段落导航相关论文