计及变压器功率损耗的多台区柔性互联协调控制研究OA
Coordinated Control Study on Flexible Interconnection of Distribution Station Areas Considering Transformer Power Losses
针对分布式电源大规模接入低压台区后传统低压配电网出现的电压越限、台区负载不平衡、变压器容量分配不均衡等问题,基于柔性互联装置的功率调控能力构建多台区互联架构,并提出一种计及变压器功率损耗的负荷调控策略,实现互联台区间有功互济、负荷均衡.首先,介绍加入电容电流反馈有源阻尼环节的柔性互联装置控制策略,为确保后续负荷调控策略的有效实施打下基础;其次,提出计及变压器功率损耗的负荷调控策略,以生成柔性互联装置功率指令;最后,仿真结果表明所提策略可以灵活控制各端口传输功率并保持母线电压稳定,且相比于传统负荷调控策略可以有效降低系统损耗.
Aiming at the problems of voltage overrun,unbalanced load in station areas,unbalanced transformer capacity distribution and other problems that occur in the traditional low-voltage distribution network after the large-scale access to low-voltage stations by distributed generator,the power regulation capability of flexible interconnection devices is utilized to construct multi-station interconnections,and a load regulation strategy taking into account the power loss of transformers is proposed to realize the mutual aid of active power and load balancing among the interconnected distribution stations areas.Firstly,the control strategy of the flexible interconnection device with the capacitor current feedback active damping link is introduced to lay the foundation for ensuring the effective implementation of the subsequent load regulation strategy.Then,the load regulation strategy taking into account the transformer power loss is proposed to generate the power command of the flexible interconnection device.Finally,the simulation results show that the proposed strategy can flexibly control the transmission power of the ports and keep the DC voltage at the same time,and can effectively reduce the system loss compared with the traditional load control strategy.
林雨润;缪希仁
福州大学电气工程与自动化学院,福建福州 350116
动力与电气工程
柔性台区柔性互联装置变压器控制策略
flexible distribution station areaflexible interconnection devicestransformercontrol strategy
《电器与能效管理技术》 2024 (009)
15-23 / 9
福建省高校产学合作项目(2023H6006)
评论