Abstract
In order to improve the seismic performance of prefabricated beam-plate joints with embedded Angle steel connectors,the stiffness degradation properties,skeleton curves,ductility properties and dissipation properties of cast-in-place beam-plate joints and prefabricated beam-plate joints with embedded Angle steel connectors were investigated experimentally.The results show that the initial stiffness value of the cast-in-place beam plate joint member is 16.8 kN/mm,which is higher than that of the prefabricated beam plate member of the embedded Angle steel connector is only 15.4 kN/mm,and the reduction is 8.3%.The dissipative energy-displacement curves of cast-in-place beam plate and prefabricated beam plate joints of embedded Angle steel connectors show a stepped-type change law.The final cumulative dissipative energy of cast-in-place beam plate joints is 12 559 kN·mm,which is higher than that of prefabricated beam plate members of embedded An-gle steel connectors,only 11 620 kN·mm,with a decrease of 7.5%.The peak load of cast-in-place beam and plate joint members is123 kN,and the peak load of prefabricated beam and plate members with embedded Angle steel connectors is 105 kN,which is reduced by 14.6%.The prefabricated beam-plate joint members with embedded Angle steel connectors have better ductility and lower bearing capacity and deform-ation resistance.关键词
装配式结构/梁板/预埋角钢/刚度性能/耗散性能/骨架曲线Key words
Prefabricated structure/Beams and plates/Embedded Angle steel/Stiffness performance/Dissipation performance/Skeleton curve分类
建筑与水利引用本文复制引用
姚银章..预埋角钢连接件装配式梁板节点抗震性能试验研究[J].江西建材,2024,(7):327-328,357,3.