| 注册
首页|期刊导航|热力发电|某300MW机组脱硝前紧凑空间粗颗粒飞灰预脱除关键技术研究及应用

某300MW机组脱硝前紧凑空间粗颗粒飞灰预脱除关键技术研究及应用

杨晓刚 潘栋 王伟 王博 兰永胜 郭雅琼 杨小金 王明生 罗志 秦建柱 舒凯 王晓冰

热力发电2024,Vol.53Issue(10):151-162,12.
热力发电2024,Vol.53Issue(10):151-162,12.DOI:10.19666/j.rlfd.202403046

某300MW机组脱硝前紧凑空间粗颗粒飞灰预脱除关键技术研究及应用

Research and application of key technologies for pre-removal of coarse particle fly ash in compact space before denitration of a 300 MW unit

杨晓刚 1潘栋 1王伟 2王博 1兰永胜 2郭雅琼 3杨小金 4王明生 5罗志 1秦建柱 4舒凯 1王晓冰1

作者信息

  • 1. 西安热工研究院有限公司,陕西 西安 710054
  • 2. 华能辛店发电有限公司,山东 淄博 255414
  • 3. 内蒙古丰电能源发电有限责任公司,内蒙古 丰镇 012100
  • 4. 华能海南发电股份有限公司东方电厂,海南 东方 572600
  • 5. 国能宁夏鸳鸯湖第一发电有限公司,宁夏 银川 751400
  • 折叠

摘要

Abstract

Due to factors such as coal quality and combustion,coarse fly ash particles in flue gas of coal-fired boiler can easily cause varying degrees of wear and tear on tail flue and denitrification catalysts.An"A-V-T"type pre-removal structure for coarse particle fly ash before denitrification is established using the flue from the economizer outlet to the denitrification system inlet of a 300 MW unit as the research object.The structure is composed of"A-type baffle enrichment+V-type high-efficiency ash collection+T-type coarse ash channel"and is placed in a large cross-section low flow velocity flue at the economizer outlet.The influence rules of different particle size distribution trajectories,removal effects and resistance before and after the arrangement of the coarse particle fly ash pre-removal device are studied through numerical simulation,and engineering application is conducted to verify the effectiveness.The numerical simulation results indicate that,the use of coarse particle removal technology has little effect on flow field state of the original system at flue gas side.As the particle size of fly ash increases,the removal rate of fly ash increases.The removal rates of fly as particles with size of 50,200,500,and 1 000 μm are 12.15%,59.40%,87.01%,and 93.62%,respectively.The removal efficiency for coarse particles with size of 200 μm and above is 85.15%.The overall ash collection rate is 15.50%,with an additional resistance of 78 Pa.For this 300 MW unit,the tests after retrofitting show that,the removal rate of coarse ash particles with size of 200 μm and above is 83.96%,the overall removal rate of ash is 14.91%,and the net increase in resistance is 73 Pa.The experimental results verify the rationality of the numerical simulation results.

关键词

脱硝/粒径分布/粗颗粒飞灰/脱除/阻力

Key words

denitration/particle size distribution/coarse particle fly ash/removal/resistance

引用本文复制引用

杨晓刚,潘栋,王伟,王博,兰永胜,郭雅琼,杨小金,王明生,罗志,秦建柱,舒凯,王晓冰..某300MW机组脱硝前紧凑空间粗颗粒飞灰预脱除关键技术研究及应用[J].热力发电,2024,53(10):151-162,12.

基金项目

中国华能集团有限公司总部科技项目(HNKJ21-H46,HNKJ22-HF48) Science and Technology Project of China Huaneng Group Co.,Ltd.(HNKJ21-H46,HNKJ22-HF48) (HNKJ21-H46,HNKJ22-HF48)