Establishing a suitable closed-loop transfer function model for the grid-connected PMSG system is the key basis in performing inter-harmonic characteristics analysis.Multiple closed-loop transfer functions can be constructed when different components of the converter controller are taken into account.However,the effect of different components of the converter controller on inter-harmonic stability analysis is not clear.In this paper,the complete transfer function,considering different loops,is first given.Based on the complete closed-loop transfer function,the DC-link,PLL and voltage forward-feed are removed step by step to derive different closed-loop transfer functions.The inter-harmonic related poles of different closed-loop transfer functions are further calculated to analyze the effect of closedloop transfer functions on inter-harmonic characteristics analysis.Finally,by performing time domain simulation,the correctness of the theoretical analysis results is verified.The results show that under the conditions of a weak AC system,each loop of the converter control system will reduce the stability of the interharmonic in the sub-synchronous frequency range and influence the inter-harmonic oscillation frequency.The transfer function needs to consider the influence of each loop to accurately calculate the inter-harmonic stability of the system.

Jingyi Li;Jianjun Yang;Xiaorong Xie;Haozhi Li;Ke Wang;Zhaohui Shi;

Key Laboratory of Far-shore Wind Power Technology of Zhejiang Province,Huadong Engineering Corporation Limited,Power China,Hangzhou 310014,China. State Key Lab of Control and Simulation of Power Systems and Generation Equipment(Dept.of Electrical Engineering,Tsinghua University),Beijing 100084,China.Key Laboratory of Far-shore Wind Power Technology of Zhejiang Province,Huadong Engineering Corporation Limited,Power China,Hangzhou 310014,China.State Key Lab of Control and Simulation of Power Systems and Generation Equipment(Dept.of Electrical Engineering,Tsinghua University),Beijing 100084,China.

数学

Closed-loop transfer functionconverter controllerinter-harmonic characteristicsPMSG

《CSEE Journal of Power and Energy Systems》 2024 (005)

P.1955-1964 / 10

supported by Research Project Huadong Engineering Corporation Limited,and National Natural Science Foundation of China(U22B20100,52321004).

10.17775/CSEEJPES.2020.03920

评论