品牌与标准化Issue(6):228-230,3.DOI:10.3969/j.issn.1674-4977.2024.06.070
血液透析机校准中的常见故障与处理
Common Trouble and Treatment in the Calibration of Hemodialysis Machine
蒋伟1
作者信息
- 1. 扬州市检验检测中心,江苏 扬州 225000
- 折叠
摘要
Abstract
Hemodialysis machines are the core equipment for treating renal failure,and their accuracy and reliability are directly related to the therapeutic outcomes for patients.This article summarizes common types of malfunctions in the calibration of hemodialysis machines and analyzes specific troubleshooting methods based on the calibration standard JJF 1353-2012 Calibration Specification of Hemodialysis Equipment,with the aim of providing some assistance to relevant personnel.关键词
血液透析机/校准/故障处理Key words
hemodialysis machine/calibration/fault treatment引用本文复制引用
蒋伟..血液透析机校准中的常见故障与处理[J].品牌与标准化,2024,(6):228-230,3.