| 注册
首页|期刊导航|肿瘤预防与治疗|光学表面监测系统辅助摆位功能在特殊体位患者上的应用

光学表面监测系统辅助摆位功能在特殊体位患者上的应用

应微 黎杰 高绪峰 王先良 吴德全 梁黎 廖雄飞

肿瘤预防与治疗2024,Vol.37Issue(10):893-897,5.
肿瘤预防与治疗2024,Vol.37Issue(10):893-897,5.DOI:10.3969/j.issn.1674-0904.2024.10.008

光学表面监测系统辅助摆位功能在特殊体位患者上的应用

Application of Optical Surface Monitoring System-Assisted Positioning on Patients in Special Positions

应微 1黎杰 1高绪峰 1王先良 1吴德全 1梁黎 1廖雄飞1

作者信息

  • 1. 610041 成都,四川省肿瘤临床医学研究中心,四川省肿瘤医院·研究所,四川省癌症防治中心,电子科技大学附属肿瘤医院放疗科
  • 折叠

摘要

Abstract

Objective:To explore the comparison of the accuracy and time between the automatic positioning of optical surface monitoring system(OSMS)and the traditional surface mark positioning in patients with special positions.Methods:Twenty radiotherapy patients in special positions were randomly selected.They were divided into two groups(A and B),10 cases in each group.Automatic setup guided by OSMS was used in group A(the OSMS group);traditional surface markers were used in positioning in group B(the surface mark group).Cone-beam CT(CBCT)scan was performed after setup.Scanned pictures were matched with the plan reference images.Translational errors in left-right(LR),superior-inferior(SI),anterior-posterior(AP)directions and the rotation errors in Roll-LR,Roll-SI,Roll-AP directions were obtained.The setup errors were corrected before implementing the treatment.Posi-tioning time in two groups were recorded before ending the treatment.Results:The errors in group A were(0.15±0.07)cm,(0.14±0.04)cm and(0.15±0.05)cm in LR,SI and AP directions,0.38°±0.14°,0.57°±0.10° and 0.55°±0.11° in Roll-LR,Roll-SI and Roll-AP directions.The errors in group B were(0.17±0.04)cm,(0.31±0.07)cm and(0.33±0.09)cm in LR,SI and AP directions,0.42°±0.15°,0.86°±0.11° and 0.81°±0.11° in Roll-LR,Roll-SI and Roll-AP directions.The differences between the two setup methods were statistically significant in y,z,Ry and Rz directions(all P<0.01).The differences between them were not statistically significant in x and Rx directions(all P>0.05).The setup time in group A was(135±32)s,in group B was(230±40)s,the difference between the two was statistically signifi-cant(P<0.01).Conclusion:OSMS-assisted automatic positioning can effectively improve the positioning accuracy,reduce the positioning time and improve work efficiency for radiotherapy patients in special positions.

关键词

光学表面监测系统(OSMS)/自动摆位/体表标记/特殊体位/摆位误差

Key words

Optical surface monitoring system/Automatic positioning/Body surface marker/Special posture/Setup error

分类

医药卫生

引用本文复制引用

应微,黎杰,高绪峰,王先良,吴德全,梁黎,廖雄飞..光学表面监测系统辅助摆位功能在特殊体位患者上的应用[J].肿瘤预防与治疗,2024,37(10):893-897,5.

肿瘤预防与治疗

OACSTPCD

1674-0904

访问量0
|
下载量0
段落导航相关论文