北京水务Issue(5):71-75,5.DOI:10.19671/j.1673-4637.2024.05.013
微气泡防冰冻技术优化研究
Optimization research on microbubble anti freezing equipment
摘要
Abstract
Preventing freezing in winter is a key task for water conservancy projects in cold regions of China.This study aims to enhance its effectiveness during freezing periods by optimizing the layout of aer-ation plates and the operational mode of microbubble anti-freezing technology.By analyzing the key fac-tors affecting the placement of aeration plates and conducting a series of experiments,the optimal depth and spacing for the aeration plates were determined.Additionally,an intelligent operating threshold based on water temperature was proposed to improve energy efficiency while ensuring the anti-freezing performance of the equipment.These research findings not only provide a scientific basis for the promo-tion and application of microbubble anti-freezing technology but also lay a solid foundation for achieving efficient and energy-saving equipment operation.关键词
微气泡防冰冻技术/技术优化/曝气盘布设/运行模式优化Key words
microbubble anti-icing technology/technical optimization/aeration tray layout/operating mode optimization分类
建筑与水利引用本文复制引用
王彦强,李记恒,刘泽,赵月,程程..微气泡防冰冻技术优化研究[J].北京水务,2024,(5):71-75,5.基金项目
北京水务科技开放项目(202304). (202304)