| 注册
首页|期刊导航|东北电力技术|350MW亚临界机组20%额定负荷深度调峰研究

350MW亚临界机组20%额定负荷深度调峰研究

张锐 高继录 蒲建业 孟祥志

东北电力技术2024,Vol.45Issue(11):24-27,36,5.
东北电力技术2024,Vol.45Issue(11):24-27,36,5.

350MW亚临界机组20%额定负荷深度调峰研究

Research on Deep Peak Shaving at 20% Rated Load for 350 MW Subcritical Units

张锐 1高继录 2蒲建业 2孟祥志2

作者信息

  • 1. 国家电投集团东北电力有限公司,辽宁 沈阳 110015
  • 2. 中电投东北能源科技有限公司,辽宁 沈阳 110179
  • 折叠

摘要

Abstract

It carries out the test of 20%rated load deep peak shaving in the No.4 350 MW unit of a power generation company.During the load reduction process,the parameters of 105 MW,90 MW,80 MW and 70 MW are selected for testing and analysis.Research finds that under 20%rated load,two B/C coal mills operate,with a minimum power generation load of 72 MW,a minimum boiler evaporation capacity of 230 t/h,a main steam pressure of 11.28 MPa,a main steam temperature of 490℃,a reheat steam temperature of 440℃,and a flue gas temperature of 290℃at the denitration inlet.Under various operating conditions,the flame detection signal and furnace negative pressure fluctuate normally.The boiler combustion is stable,and the operating parameters of the steam turbine are normal.The environmental indicators are within the qualified range,and the auxiliary equipment operates smoothly.It provides reference for the subsequent development of reasonable equipment transformation and logic optimization scheme.

关键词

亚临界机组/20%额定负荷/深度调峰

Key words

subcritical units/20% rated load/deep peak shaving