爆破器材2024,Vol.53Issue(6):28-32,40,6.DOI:10.3969/j.issn.1001-8352.2024.06.005
电点火器输出p-t曲线出现负压的异常情况分析
Analysis of Abnormal Conditions of Negative Pressure in the Output p-t Curves of the Electric Igniter
袁长宏 1袁玉红 1谭玉明 1曹平1
作者信息
- 1. 安徽红星机电科技股份有限公司(安徽 合肥,230011)
- 折叠
摘要
Abstract
Fault tree analysis,equivalent circuit analysis,and experimental verification were conducted to investi-gate the negative pressure situation that occurred during the ignition test of an electric igniter for a certain type of missile en-gine.Finally,the cause of the fault was found to be the insulation performance failure of the product after ignition,resul-ting in the coupling of the ignition circuit and the testing circuit to form a current loop,which in turn caused negative pres-sure at the output terminal of the charge amplifier.Further theoretical analysis and experimental verification were conducted on the occurrence of negative pressure during the ignition tests of various pyrotechnic devices.The results indicate that negative pressure only occurs during the testing process using piezoelectric sensors,while it does not occur when using strain gauges.It could provide a reference for analyzing the abnormal output p-t curve of electric igniter products.关键词
电点火器/p-t曲线/负压Key words
electric igniter/p-t curve/negative pressure分类
化学工程引用本文复制引用