首页|期刊导航|北京生物医学工程|基于腹电信号的自动胎儿诊断算法的研究

基于腹电信号的自动胎儿诊断算法的研究

王铭涵 李广飞 冯永康 李雅爽 刘国莉 杨益民

北京生物医学工程2024,Vol.43Issue(6):606-612,7.
北京生物医学工程2024,Vol.43Issue(6):606-612,7.DOI:10.3969/j.issn.1002-3208.2024.06.008

基于腹电信号的自动胎儿诊断算法的研究

Study of automatic fetal diagnostic algorithms based on abdominal signals

王铭涵 1李广飞 2冯永康 1李雅爽 1刘国莉 3杨益民2

作者信息

  • 1. 北京工业大学化学与生命科学学院(北京 100124)
  • 2. 北京工业大学化学与生命科学学院(北京 100124)||北京国际智能生理测量与临床转化科技合作基地(北京 100124)
  • 3. 北京大学人民医院产科(北京 100044)
  • 折叠

摘要

Abstract

Objective Electronic fetal monitoring is an important means of assessing the intrauterine status of the fetus by continuously monitoring changes in fetal heart rate and uterine contractions.However traditional manual diagnosis of electronic fetal monitoring has the limitations of high subjectivity and low consistency.Compared to the ultrasound Doppler method,the transabdominal electrical signal method permits longer monitoring and is less affected by individual differences,yet there is a lack of accurate automated fetal diagnostic algorithms based on abdominal signals in China.For this reason,this study proposes an innovative algorithm that aims to improve the accuracy and efficiency of fetal diagnosis and to provide domestic clinicians with an effective decision-support tool to enhance the quality of healthcare services.Methods This algorithm uses a stable and effective multitask deep learning network to analyze the fetal heart rate extracted from the abdominal electrical signals to obtain the fetal heart rate parameters(baseline,acceleration and deceleration starting and stopping times),and the electrohysterogram signals obtained by filtering the abdominal signals are used for the recognition of uterine contractions to obtain the parameters of uterine contractions(uterine contraction frequency and starting and stopping times).These above-extracted parameters are sorted out and combined with the expert consensus on the application of electronic fetal monitoring for the diagnosis of fetal monitoring results.Results By analyzing the 20-minute monitoring recordings of 89 cases of simultaneous use of abdominal dynamic fetal monitor and Doppler fetal monitor,the algorithm demonstrates a sensitivity of 76.09%and a positive predictive value of 97.22%for the identification of none-stress test reactivity type,and a sensitivity of 88.89%and a positive predictive value of 68.09%for the contraction stress test category I,and an overall accuracy of 77.53%.Conclusions The algorithm demonstrates a high degree of consistency in comparisons with physicians'diagnostic results,providing an innovative aid for improving the quality of clinical decision-making and healthcare delivery.

关键词

电子胎心监护/胎心率/宫缩/腹电信号/子宫肌电信号

Key words

electronic fetal monitoring/fetal heart rate/uterine contraction/abdominal signal/electrohysterogram

分类

医药卫生

引用本文复制引用

王铭涵,李广飞,冯永康,李雅爽,刘国莉,杨益民..基于腹电信号的自动胎儿诊断算法的研究[J].北京生物医学工程,2024,43(6):606-612,7.